R&D of KLM Upgrade for Direct Measurement of Neutral Hadron Momentum via Time-of-Flight in Belle II

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Wang, Xiyang, Zhang, Hongyu, Zou, Shiming, Bai, Zibing, Fang, Deqing, Huang, Kairui, Liu, Ziyu, Ma, Yugang, Meng, Weiqi, Wang, Ting, Wang, Xiaolong, Xie, Shiqing, Yang, Mingjie, Yin, Junhao, Yuan, Mingkuan, Zhuang, Wanyi
Natura: Preprint
Pubblicazione: 2025
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866914023608418304
author Wang, Xiyang
Zhang, Hongyu
Zou, Shiming
Bai, Zibing
Fang, Deqing
Huang, Kairui
Liu, Ziyu
Ma, Yugang
Meng, Weiqi
Wang, Ting
Wang, Xiaolong
Xie, Shiqing
Yang, Mingjie
Yin, Junhao
Yuan, Mingkuan
Zhuang, Wanyi
author_facet Wang, Xiyang
Zhang, Hongyu
Zou, Shiming
Bai, Zibing
Fang, Deqing
Huang, Kairui
Liu, Ziyu
Ma, Yugang
Meng, Weiqi
Wang, Ting
Wang, Xiaolong
Xie, Shiqing
Yang, Mingjie
Yin, Junhao
Yuan, Mingkuan
Zhuang, Wanyi
contents Accurate momentum determination of a neutral hadron, such as a KL meson or a neutron, remains a significant challenge in particle physics and nuclear physics experiments. The Belle II experiment presents an opportunity to address this challenge through an upgrade incorporating Time-of-Flight (TOF) capability for its large KL and Muon Detector (KLM). We investigate the feasibility of momentum determination via TOF measurement. To achieve high time resolution for the KLM upgrade, we conduct research and development of cost-effective plastic scintillators in collaboration with GaoNengKeDi Company, and technology utilizing silicon photomultipliers(SiPMs) arrays. A bulk attenuation length of 120 \pm 7 cm has been achieved with a 135 cm-long sample, along with a time resolution of 70 \pm 7 ps at its midpoint. A 50 cm-long scintillator demonstrates an exceptional time resolution of 47 \pm 2 ps. These results highlight the potential of the proposed technology for improving neutral hadron momentum measurements in an upgraded Belle II KLM detector.
format Preprint
id arxiv_https___arxiv_org_abs_2503_06128
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle R&D of KLM Upgrade for Direct Measurement of Neutral Hadron Momentum via Time-of-Flight in Belle II
Wang, Xiyang
Zhang, Hongyu
Zou, Shiming
Bai, Zibing
Fang, Deqing
Huang, Kairui
Liu, Ziyu
Ma, Yugang
Meng, Weiqi
Wang, Ting
Wang, Xiaolong
Xie, Shiqing
Yang, Mingjie
Yin, Junhao
Yuan, Mingkuan
Zhuang, Wanyi
Instrumentation and Detectors
Accurate momentum determination of a neutral hadron, such as a KL meson or a neutron, remains a significant challenge in particle physics and nuclear physics experiments. The Belle II experiment presents an opportunity to address this challenge through an upgrade incorporating Time-of-Flight (TOF) capability for its large KL and Muon Detector (KLM). We investigate the feasibility of momentum determination via TOF measurement. To achieve high time resolution for the KLM upgrade, we conduct research and development of cost-effective plastic scintillators in collaboration with GaoNengKeDi Company, and technology utilizing silicon photomultipliers(SiPMs) arrays. A bulk attenuation length of 120 \pm 7 cm has been achieved with a 135 cm-long sample, along with a time resolution of 70 \pm 7 ps at its midpoint. A 50 cm-long scintillator demonstrates an exceptional time resolution of 47 \pm 2 ps. These results highlight the potential of the proposed technology for improving neutral hadron momentum measurements in an upgraded Belle II KLM detector.
title R&D of KLM Upgrade for Direct Measurement of Neutral Hadron Momentum via Time-of-Flight in Belle II
topic Instrumentation and Detectors
url https://arxiv.org/abs/2503.06128