New CCD Driving Technique to Suppress Anomalous Charge Intrusion from Outside the Imaging Area for Soft X-ray Imager of Xtend onboard XRISM
Fuente:
arXiv
Enregistré dans:
| Auteurs principaux: | , , , , , , , , , , , , , , , , , , , , , , , , |
|---|---|
| Format: | Preprint |
| Publié: |
2025
|
| Sujets: | |
| Accès en ligne: | |
| Tags: |
Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
|
| _version_ | 1866929750902046720 |
|---|---|
| author | Noda, Hirofumi Aoyagi, Mio Mori, Koji Tomida, Hiroshi Nakajima, Hiroshi Tanaka, Takaaki Suzuki, Hiromasa Murakami, Hiroshi Uchida, Hiroyuki Tsuru, Takeshi G. Miyazaki, Keitaro Kusunoki, Kohei Kanemaru, Yoshiaki Aoki, Yuma Nobukawa, Kumiko Nobukawa, Masayoshi Shima, Kohei Yoshimoto, Marina Asakura, Kazunori Matsumoto, Hironori Yoneyama, Tomokage Kobayashi, Shogo B. Hagino, Kouichi Uchiyama, Hideki Hayashida, Kiyoshi |
| author_facet | Noda, Hirofumi Aoyagi, Mio Mori, Koji Tomida, Hiroshi Nakajima, Hiroshi Tanaka, Takaaki Suzuki, Hiromasa Murakami, Hiroshi Uchida, Hiroyuki Tsuru, Takeshi G. Miyazaki, Keitaro Kusunoki, Kohei Kanemaru, Yoshiaki Aoki, Yuma Nobukawa, Kumiko Nobukawa, Masayoshi Shima, Kohei Yoshimoto, Marina Asakura, Kazunori Matsumoto, Hironori Yoneyama, Tomokage Kobayashi, Shogo B. Hagino, Kouichi Uchiyama, Hideki Hayashida, Kiyoshi |
| contents | The Soft X-ray Imager (SXI) is an X-ray CCD camera of the Xtend system onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), which was successfully launched on September 7, 2023 (JST). During ground cooling tests of the CCDs in 2020/2021, using the flight-model detector housing, electronic boards, and a mechanical cooler, we encountered an unexpected issue. Anomalous charges appeared outside the imaging area of the CCDs and intruded into the imaging area, causing pulse heights to stick to the maximum value over a wide region. Although this issue has not occurred in subsequent tests or in orbit so far, it could seriously affect the imaging and spectroscopic performance of the SXI if it were to happen in the future. Through experiments with non-flight-model detector components, we successfully reproduced the issue and identified that the anomalous charges intrude via the potential structure created by the charge injection electrode at the top of the imaging area. To prevent anomalous charge intrusion and maintain imaging and spectroscopic performance that satisfies the requirements, even if this issue occurs in orbit, we developed a new CCD driving technique. This technique is different from the normal operation in terms of potential structure and its changes during imaging and charge injection. In this paper, we report an overview of the anomalous charge issue, the related potential structures, the development of the new CCD driving technique to prevent the issue, the imaging and spectroscopic performance of the new technique, and the results of experiments to investigate the cause of anomalous charges. |
| format | Preprint |
| id |
arxiv_https___arxiv_org_abs_2503_06760 |
| institution | arXiv |
| publishDate | 2025 |
| record_format | arxiv |
| spellingShingle | New CCD Driving Technique to Suppress Anomalous Charge Intrusion from Outside the Imaging Area for Soft X-ray Imager of Xtend onboard XRISM Noda, Hirofumi Aoyagi, Mio Mori, Koji Tomida, Hiroshi Nakajima, Hiroshi Tanaka, Takaaki Suzuki, Hiromasa Murakami, Hiroshi Uchida, Hiroyuki Tsuru, Takeshi G. Miyazaki, Keitaro Kusunoki, Kohei Kanemaru, Yoshiaki Aoki, Yuma Nobukawa, Kumiko Nobukawa, Masayoshi Shima, Kohei Yoshimoto, Marina Asakura, Kazunori Matsumoto, Hironori Yoneyama, Tomokage Kobayashi, Shogo B. Hagino, Kouichi Uchiyama, Hideki Hayashida, Kiyoshi Instrumentation and Methods for Astrophysics High Energy Physics - Experiment Instrumentation and Detectors The Soft X-ray Imager (SXI) is an X-ray CCD camera of the Xtend system onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), which was successfully launched on September 7, 2023 (JST). During ground cooling tests of the CCDs in 2020/2021, using the flight-model detector housing, electronic boards, and a mechanical cooler, we encountered an unexpected issue. Anomalous charges appeared outside the imaging area of the CCDs and intruded into the imaging area, causing pulse heights to stick to the maximum value over a wide region. Although this issue has not occurred in subsequent tests or in orbit so far, it could seriously affect the imaging and spectroscopic performance of the SXI if it were to happen in the future. Through experiments with non-flight-model detector components, we successfully reproduced the issue and identified that the anomalous charges intrude via the potential structure created by the charge injection electrode at the top of the imaging area. To prevent anomalous charge intrusion and maintain imaging and spectroscopic performance that satisfies the requirements, even if this issue occurs in orbit, we developed a new CCD driving technique. This technique is different from the normal operation in terms of potential structure and its changes during imaging and charge injection. In this paper, we report an overview of the anomalous charge issue, the related potential structures, the development of the new CCD driving technique to prevent the issue, the imaging and spectroscopic performance of the new technique, and the results of experiments to investigate the cause of anomalous charges. |
| title | New CCD Driving Technique to Suppress Anomalous Charge Intrusion from Outside the Imaging Area for Soft X-ray Imager of Xtend onboard XRISM |
| topic | Instrumentation and Methods for Astrophysics High Energy Physics - Experiment Instrumentation and Detectors |
| url | https://arxiv.org/abs/2503.06760 |