From Slices to Sequences: Autoregressive Tracking Transformer for Cohesive and Consistent 3D Lymph Node Detection in CT Scans

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Yu, Qinji, Wang, Yirui, Yan, Ke, Zheng, Dandan, Ai, Dashan, Guo, Dazhou, Ji, Zhanghexuan, Su, Yanzhou, Bian, Yun, Shen, Na, Ding, Xiaowei, Lu, Le, Ye, Xianghua, Jin, Dakai
Format: Preprint
Publié: 2025
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866910872416288768
author Yu, Qinji
Wang, Yirui
Yan, Ke
Zheng, Dandan
Ai, Dashan
Guo, Dazhou
Ji, Zhanghexuan
Su, Yanzhou
Bian, Yun
Shen, Na
Ding, Xiaowei
Lu, Le
Ye, Xianghua
Jin, Dakai
author_facet Yu, Qinji
Wang, Yirui
Yan, Ke
Zheng, Dandan
Ai, Dashan
Guo, Dazhou
Ji, Zhanghexuan
Su, Yanzhou
Bian, Yun
Shen, Na
Ding, Xiaowei
Lu, Le
Ye, Xianghua
Jin, Dakai
contents Lymph node (LN) assessment is an essential task in the routine radiology workflow, providing valuable insights for cancer staging, treatment planning and beyond. Identifying scatteredly-distributed and low-contrast LNs in 3D CT scans is highly challenging, even for experienced clinicians. Previous lesion and LN detection methods demonstrate effectiveness of 2.5D approaches (i.e, using 2D network with multi-slice inputs), leveraging pretrained 2D model weights and showing improved accuracy as compared to separate 2D or 3D detectors. However, slice-based 2.5D detectors do not explicitly model inter-slice consistency for LN as a 3D object, requiring heuristic post-merging steps to generate final 3D LN instances, which can involve tuning a set of parameters for each dataset. In this work, we formulate 3D LN detection as a tracking task and propose LN-Tracker, a novel LN tracking transformer, for joint end-to-end detection and 3D instance association. Built upon DETR-based detector, LN-Tracker decouples transformer decoder's query into the track and detection groups, where the track query autoregressively follows previously tracked LN instances along the z-axis of a CT scan. We design a new transformer decoder with masked attention module to align track query's content to the context of current slice, meanwhile preserving detection query's high accuracy in current slice. An inter-slice similarity loss is introduced to encourage cohesive LN association between slices. Extensive evaluation on four lymph node datasets shows LN-Tracker's superior performance, with at least 2.7% gain in average sensitivity when compared to other top 3D/2.5D detectors. Further validation on public lung nodule and prostate tumor detection tasks confirms the generalizability of LN-Tracker as it achieves top performance on both tasks.
format Preprint
id arxiv_https___arxiv_org_abs_2503_07933
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle From Slices to Sequences: Autoregressive Tracking Transformer for Cohesive and Consistent 3D Lymph Node Detection in CT Scans
Yu, Qinji
Wang, Yirui
Yan, Ke
Zheng, Dandan
Ai, Dashan
Guo, Dazhou
Ji, Zhanghexuan
Su, Yanzhou
Bian, Yun
Shen, Na
Ding, Xiaowei
Lu, Le
Ye, Xianghua
Jin, Dakai
Computer Vision and Pattern Recognition
Lymph node (LN) assessment is an essential task in the routine radiology workflow, providing valuable insights for cancer staging, treatment planning and beyond. Identifying scatteredly-distributed and low-contrast LNs in 3D CT scans is highly challenging, even for experienced clinicians. Previous lesion and LN detection methods demonstrate effectiveness of 2.5D approaches (i.e, using 2D network with multi-slice inputs), leveraging pretrained 2D model weights and showing improved accuracy as compared to separate 2D or 3D detectors. However, slice-based 2.5D detectors do not explicitly model inter-slice consistency for LN as a 3D object, requiring heuristic post-merging steps to generate final 3D LN instances, which can involve tuning a set of parameters for each dataset. In this work, we formulate 3D LN detection as a tracking task and propose LN-Tracker, a novel LN tracking transformer, for joint end-to-end detection and 3D instance association. Built upon DETR-based detector, LN-Tracker decouples transformer decoder's query into the track and detection groups, where the track query autoregressively follows previously tracked LN instances along the z-axis of a CT scan. We design a new transformer decoder with masked attention module to align track query's content to the context of current slice, meanwhile preserving detection query's high accuracy in current slice. An inter-slice similarity loss is introduced to encourage cohesive LN association between slices. Extensive evaluation on four lymph node datasets shows LN-Tracker's superior performance, with at least 2.7% gain in average sensitivity when compared to other top 3D/2.5D detectors. Further validation on public lung nodule and prostate tumor detection tasks confirms the generalizability of LN-Tracker as it achieves top performance on both tasks.
title From Slices to Sequences: Autoregressive Tracking Transformer for Cohesive and Consistent 3D Lymph Node Detection in CT Scans
topic Computer Vision and Pattern Recognition
url https://arxiv.org/abs/2503.07933