Calibration of Solid State Nuclear Track Detectors for Rare Event Searches

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Kalliokoski, M., Levi, G., Maulik, A., Ostrovskiy, I., Patrizii, L., Pinfold, J., Sahnoun, Z., Sirri, G., Soluk, R., Staelens, M., Togo, V., Upreti, A.
Format: Preprint
Publié: 2025
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866914072076746752
author Kalliokoski, M.
Levi, G.
Maulik, A.
Ostrovskiy, I.
Patrizii, L.
Pinfold, J.
Sahnoun, Z.
Sirri, G.
Soluk, R.
Staelens, M.
Togo, V.
Upreti, A.
author_facet Kalliokoski, M.
Levi, G.
Maulik, A.
Ostrovskiy, I.
Patrizii, L.
Pinfold, J.
Sahnoun, Z.
Sirri, G.
Soluk, R.
Staelens, M.
Togo, V.
Upreti, A.
contents The calibration of the CR39 and Makrofol Nuclear Track Detectors of the MoEDAL experiment at the CERN-LHC was performed by exposing stacks of detector foils to heavy ion beams with energies ranging from 340 MeV/nucleon to 150 GeV/nucleon. After chemical etching, the base areas and lengths of etch-pit cones were measured using automatic and manual optical microscopes. The response of the detectors, as measured by the ratio of the track-etching rate over the bulk-etching rate, was determined over a range extending from their threshold at Z/$β\sim7$ and $\sim50$ for CR39 and Makrofol, respectively, up to Z/$β\sim92$
format Preprint
id arxiv_https___arxiv_org_abs_2503_09495
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Calibration of Solid State Nuclear Track Detectors for Rare Event Searches
Kalliokoski, M.
Levi, G.
Maulik, A.
Ostrovskiy, I.
Patrizii, L.
Pinfold, J.
Sahnoun, Z.
Sirri, G.
Soluk, R.
Staelens, M.
Togo, V.
Upreti, A.
Instrumentation and Detectors
The calibration of the CR39 and Makrofol Nuclear Track Detectors of the MoEDAL experiment at the CERN-LHC was performed by exposing stacks of detector foils to heavy ion beams with energies ranging from 340 MeV/nucleon to 150 GeV/nucleon. After chemical etching, the base areas and lengths of etch-pit cones were measured using automatic and manual optical microscopes. The response of the detectors, as measured by the ratio of the track-etching rate over the bulk-etching rate, was determined over a range extending from their threshold at Z/$β\sim7$ and $\sim50$ for CR39 and Makrofol, respectively, up to Z/$β\sim92$
title Calibration of Solid State Nuclear Track Detectors for Rare Event Searches
topic Instrumentation and Detectors
url https://arxiv.org/abs/2503.09495