Finger-to-Chest Style Transfer-assisted Deep Learning Method For Photoplethysmogram Waveform Restoration with Timing Preservation

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Pagotto, Sara Maria, Tognoni, Federico, Rossi, Matteo, Bovio, Dario, Salito, Caterina, Mainardi, Luca, Cerveri, Pietro
Format: Preprint
Published: 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866916655043444736
author Pagotto, Sara Maria
Tognoni, Federico
Rossi, Matteo
Bovio, Dario
Salito, Caterina
Mainardi, Luca
Cerveri, Pietro
author_facet Pagotto, Sara Maria
Tognoni, Federico
Rossi, Matteo
Bovio, Dario
Salito, Caterina
Mainardi, Luca
Cerveri, Pietro
contents Wearable measurements, such as those obtained by photoplethysmogram (PPG) sensors are highly susceptible to motion artifacts and noise, affecting cardiovascular measures. Chest-acquired PPG signals are especially vulnerable, with signal degradation primarily resulting from lower perfusion, breathing-induced motion, and mechanical interference from chest movements. Traditional restoration methods often degrade the signal, and supervised deep learning (DL) struggles with random and systematic distortions, requiring very large datasets for successful training. To efficiently restore chest PPG waveform, we propose a style transfer-assisted cycle-consistent generative adversarial network, called starGAN, whose performance is evaluated on a three-channel PPG signal (red, green,and infrared) acquired by a chest-worn multi-modal sensor, called Soundi. Two identical devices are adopted, one sensor to collect the PPG signal on the chest, considered to feature low quality and undergoing restoration, and another sensor to obtain a high-quality PPG signal measured on the finger, considered the reference signal. Extensive validation over some 8,000 5-second chunks collected from 40 subjects showed about 90% correlation of the restored chest PPG with the reference finger PPG, with a 30% improvement over raw chest PPG. Likewise, the signal-to-noise ratio improved on average of about 125%, over the three channels. The agreement with heart-rate computed from concurrent ECG was extremely high, overcoming 84% on average. These results demonstrate effective signal restoration, comparable with findings in recent literature papers. Significance: PPG signals collected from wearable devices are highly susceptible to artifacts, making innovative AI-based techniques fundamental towards holistic health assessments in a single device.
format Preprint
id arxiv_https___arxiv_org_abs_2503_13496
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Finger-to-Chest Style Transfer-assisted Deep Learning Method For Photoplethysmogram Waveform Restoration with Timing Preservation
Pagotto, Sara Maria
Tognoni, Federico
Rossi, Matteo
Bovio, Dario
Salito, Caterina
Mainardi, Luca
Cerveri, Pietro
Signal Processing
Machine Learning
Quantitative Methods
Wearable measurements, such as those obtained by photoplethysmogram (PPG) sensors are highly susceptible to motion artifacts and noise, affecting cardiovascular measures. Chest-acquired PPG signals are especially vulnerable, with signal degradation primarily resulting from lower perfusion, breathing-induced motion, and mechanical interference from chest movements. Traditional restoration methods often degrade the signal, and supervised deep learning (DL) struggles with random and systematic distortions, requiring very large datasets for successful training. To efficiently restore chest PPG waveform, we propose a style transfer-assisted cycle-consistent generative adversarial network, called starGAN, whose performance is evaluated on a three-channel PPG signal (red, green,and infrared) acquired by a chest-worn multi-modal sensor, called Soundi. Two identical devices are adopted, one sensor to collect the PPG signal on the chest, considered to feature low quality and undergoing restoration, and another sensor to obtain a high-quality PPG signal measured on the finger, considered the reference signal. Extensive validation over some 8,000 5-second chunks collected from 40 subjects showed about 90% correlation of the restored chest PPG with the reference finger PPG, with a 30% improvement over raw chest PPG. Likewise, the signal-to-noise ratio improved on average of about 125%, over the three channels. The agreement with heart-rate computed from concurrent ECG was extremely high, overcoming 84% on average. These results demonstrate effective signal restoration, comparable with findings in recent literature papers. Significance: PPG signals collected from wearable devices are highly susceptible to artifacts, making innovative AI-based techniques fundamental towards holistic health assessments in a single device.
title Finger-to-Chest Style Transfer-assisted Deep Learning Method For Photoplethysmogram Waveform Restoration with Timing Preservation
topic Signal Processing
Machine Learning
Quantitative Methods
url https://arxiv.org/abs/2503.13496