| author | Yang, Yitong Naeem, Muhammad Van Assen, Marly Yerly, Jerome Piccini, Davide Stuber, Matthias Oshinski, John Chung, Matthias |
| author_facet | Yang, Yitong Naeem, Muhammad Van Assen, Marly Yerly, Jerome Piccini, Davide Stuber, Matthias Oshinski, John Chung, Matthias |
| contents | Purpose: Ferumoxytal-enhanced 5D free-running whole heart CMR provides image quality comparable to CTA, but requires hours-long reconstruction time, preventing clinical usage. This study developed a variable projection augmented Lagrangian (VPAL) method for 5D motion-resolved image reconstruction and compared it with alternating direction method of multipliers (ADMM) in five numerical simulations and 15 in-vivo pediatric data set.
Approach: Relative error of the reconstructed images against the ground-truth images was assessed in numerical simulations. In-vivo analysis compared reconstruction time, mid-short axis (SA) blood-myocardium sharpness, left ventricular ejection fraction (LVEF), and a radiologist's image quality ratings between VPAL and ADMM. A paired t-test (p<0.05) was used to determine statistical significance, while linear regression and Bland-Altman analysis for agreement assessments.
Results: VPAL and ADMM had similar relative errors compared to the ground truth, p = 0.07. In in-vivo datasets, VPAL reduced the reconstruction time from 16.3 +/- 3.6 hours (ADMM) to 4.7 +/- 1.1 hours (VPAL), p=1e-10. Blood-myocardium border sharpness in VPAL closely correlates to ADMM , R^2 = 0.97. The LVEFs values measured by VPAL and ADMM reconstructions are largely similar, 56 +/- 6 % in ADMM and 56 +/- 6 % in VPAL, p=0.55. Both VPAL and ADMM reconstructions have good to excellent diagnostic ratings (VPAL vs. ADMM: 3.9 +/- 0.3 vs. 3.8 +/- 0.4 in 2-chamber; 3.9 +/- 0.4 vs. 3.9 +/- in 4-chamber; 3.7 +/- 0.5 vs. 3.7 +/- 0.5 in mid-SA reformatted views. Conclusion: VPAL enables faster reconstruction than ADMM while maintaining equivalent image quality for functional assessments, supporting its potential for clinical use. |
| format | Preprint |
| id |
arxiv_https___arxiv_org_abs_2503_15711 |
| institution | arXiv |
| publishDate | 2025 |
| record_format | arxiv |
| spellingShingle | VPAL: A novel method to reduce reconstruction time for 5D free-running imaging Yang, Yitong Naeem, Muhammad Van Assen, Marly Yerly, Jerome Piccini, Davide Stuber, Matthias Oshinski, John Chung, Matthias Medical Physics Numerical Analysis Purpose: Ferumoxytal-enhanced 5D free-running whole heart CMR provides image quality comparable to CTA, but requires hours-long reconstruction time, preventing clinical usage. This study developed a variable projection augmented Lagrangian (VPAL) method for 5D motion-resolved image reconstruction and compared it with alternating direction method of multipliers (ADMM) in five numerical simulations and 15 in-vivo pediatric data set. Approach: Relative error of the reconstructed images against the ground-truth images was assessed in numerical simulations. In-vivo analysis compared reconstruction time, mid-short axis (SA) blood-myocardium sharpness, left ventricular ejection fraction (LVEF), and a radiologist's image quality ratings between VPAL and ADMM. A paired t-test (p<0.05) was used to determine statistical significance, while linear regression and Bland-Altman analysis for agreement assessments. Results: VPAL and ADMM had similar relative errors compared to the ground truth, p = 0.07. In in-vivo datasets, VPAL reduced the reconstruction time from 16.3 +/- 3.6 hours (ADMM) to 4.7 +/- 1.1 hours (VPAL), p=1e-10. Blood-myocardium border sharpness in VPAL closely correlates to ADMM , R^2 = 0.97. The LVEFs values measured by VPAL and ADMM reconstructions are largely similar, 56 +/- 6 % in ADMM and 56 +/- 6 % in VPAL, p=0.55. Both VPAL and ADMM reconstructions have good to excellent diagnostic ratings (VPAL vs. ADMM: 3.9 +/- 0.3 vs. 3.8 +/- 0.4 in 2-chamber; 3.9 +/- 0.4 vs. 3.9 +/- in 4-chamber; 3.7 +/- 0.5 vs. 3.7 +/- 0.5 in mid-SA reformatted views. Conclusion: VPAL enables faster reconstruction than ADMM while maintaining equivalent image quality for functional assessments, supporting its potential for clinical use. |
| title | VPAL: A novel method to reduce reconstruction time for 5D free-running imaging |
| topic | Medical Physics Numerical Analysis |
| url | https://arxiv.org/abs/2503.15711 |