Performance of neutron and proton irradiated AC-LGAD sensors
Fuente:
arXiv
Gespeichert in:
| Hauptverfasser: | , , , , , , , , , , , , , , , , , , , |
|---|---|
| Format: | Preprint |
| Veröffentlicht: |
2025
|
| Schlagworte: | |
| Online-Zugang: | |
| Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
| _version_ | 1866909551014445056 |
|---|---|
| author | Stage, G. Borjigin, A. Ding, J. Davis, M. Beringer, S. Gignac, M. McKinney-Martinez, F. Mazza, S. M. Molnar, A. Ott, J. Sadrozinski, H. F. -W. Schumm, B. Seiden, A. Shin, T. Wilder, M. Kramberger, G. Mandic, I. Seidel, S. Si, J. Novotny, R. |
| author_facet | Stage, G. Borjigin, A. Ding, J. Davis, M. Beringer, S. Gignac, M. McKinney-Martinez, F. Mazza, S. M. Molnar, A. Ott, J. Sadrozinski, H. F. -W. Schumm, B. Seiden, A. Shin, T. Wilder, M. Kramberger, G. Mandic, I. Seidel, S. Si, J. Novotny, R. |
| contents | Characterization of strip and pixel AC-LGAD devices with both laser TCT and probe station (IV/CV) will be shown on AC-LGADs irradiated with 1 MeV reactor neutrons at JSI/Ljubljana and with 400~MeV protons at FNAL ITA to fluences from 1e13~$n_{eq}/cm^2$ to a few times 1e15~$n_{eq}/cm^2$. This study was conducted within the scope of the ePIC detector time of flight (TOF) layer R\&D program at the EIC, which will feature AC-LGADs with strip and pixel geometry. Sensors in the TOF layer will receive up to 1e13~$n_{eq}/cm^2$ fluence over the lifetime of the experiment. |
| format | Preprint |
| id |
arxiv_https___arxiv_org_abs_2503_16658 |
| institution | arXiv |
| publishDate | 2025 |
| record_format | arxiv |
| spellingShingle | Performance of neutron and proton irradiated AC-LGAD sensors Stage, G. Borjigin, A. Ding, J. Davis, M. Beringer, S. Gignac, M. McKinney-Martinez, F. Mazza, S. M. Molnar, A. Ott, J. Sadrozinski, H. F. -W. Schumm, B. Seiden, A. Shin, T. Wilder, M. Kramberger, G. Mandic, I. Seidel, S. Si, J. Novotny, R. Instrumentation and Detectors High Energy Physics - Experiment Characterization of strip and pixel AC-LGAD devices with both laser TCT and probe station (IV/CV) will be shown on AC-LGADs irradiated with 1 MeV reactor neutrons at JSI/Ljubljana and with 400~MeV protons at FNAL ITA to fluences from 1e13~$n_{eq}/cm^2$ to a few times 1e15~$n_{eq}/cm^2$. This study was conducted within the scope of the ePIC detector time of flight (TOF) layer R\&D program at the EIC, which will feature AC-LGADs with strip and pixel geometry. Sensors in the TOF layer will receive up to 1e13~$n_{eq}/cm^2$ fluence over the lifetime of the experiment. |
| title | Performance of neutron and proton irradiated AC-LGAD sensors |
| topic | Instrumentation and Detectors High Energy Physics - Experiment |
| url | https://arxiv.org/abs/2503.16658 |