Real-time diffuse correlation spectroscopy with a chip-based correlator for measuring human cerebral blood flow and brain function

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Wang, Quan, Hua, Yuanyuan, Li, Chenxu, Yuan, Zhizheng, Wang, Jing, Erdogan, Ahmet T., Chen, Hanqing, Huang, Xunting, Wojtkiewicz, Maciej, Gorman, Alistair, Pan, Mingliang, Zhang, Yuanzhe, Wang, Yining, Finlayson, Neil, Bi, Renzhe, Henderson, Robert K., Yuan, Zhen, Li, David Day-Uei
Format: Preprint
Publié: 2025
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866917475598204928
author Wang, Quan
Hua, Yuanyuan
Li, Chenxu
Yuan, Zhizheng
Wang, Jing
Erdogan, Ahmet T.
Chen, Hanqing
Huang, Xunting
Wojtkiewicz, Maciej
Gorman, Alistair
Pan, Mingliang
Zhang, Yuanzhe
Wang, Yining
Finlayson, Neil
Bi, Renzhe
Henderson, Robert K.
Yuan, Zhen
Li, David Day-Uei
author_facet Wang, Quan
Hua, Yuanyuan
Li, Chenxu
Yuan, Zhizheng
Wang, Jing
Erdogan, Ahmet T.
Chen, Hanqing
Huang, Xunting
Wojtkiewicz, Maciej
Gorman, Alistair
Pan, Mingliang
Zhang, Yuanzhe
Wang, Yining
Finlayson, Neil
Bi, Renzhe
Henderson, Robert K.
Yuan, Zhen
Li, David Day-Uei
contents Diffuse correlation spectroscopy (DCS) is a noninvasive optical technique that probes microvascular blood flow in deep tissues. Here, we present and validate a new on-chip hardware correlator for high-speed DCS measurements. The correlator is embedded in a custom-built 512 x 512 single-photon avalanche diode (SPAD) array named ATLAS, which computes intensity autocorrelation functions directly on-chip at a sampling rate of 116 Hz - the fastest DCS acquisition reported to date. Unlike conventional DCS systems that suffer from low light throughput and therefore cannot resolve cardiac pulsations at source-detector separations (rho) beyond 30 mm, our massively parallel on-chip architecture computes autocorrelations within each macropixel, eliminating the data-throughput bottleneck. This enables high-SNR, real-time detection of pulsatile blood flow even at rho = 50 mm on the human forehead. In phantom experiments at rho = 25 mm, ATLAS-DCS achieves a 12-fold improvement in signal-to-noise ratio over a conventional single-channel DCS instrument while operating at 116 Hz. In human subjects, we resolve functional hyperemia during a mental arithmetic task at rho = 30 mm. Furthermore, we integrate ATLAS DCS with a frequency-domain near-infrared spectroscopy (FD-NIRS) module, enabling simultaneous monitoring of blood flow and tissue oxygenation. With this combined system, we can concurrently resolve core hemodynamic parameters. The on-chip parallelized DCS design substantially improves detection speed, depth sensitivity, and real-time capability, paving the way for wearable, high-speed cerebral blood flow monitoring in both clinical and research settings.
format Preprint
id arxiv_https___arxiv_org_abs_2503_17459
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Real-time diffuse correlation spectroscopy with a chip-based correlator for measuring human cerebral blood flow and brain function
Wang, Quan
Hua, Yuanyuan
Li, Chenxu
Yuan, Zhizheng
Wang, Jing
Erdogan, Ahmet T.
Chen, Hanqing
Huang, Xunting
Wojtkiewicz, Maciej
Gorman, Alistair
Pan, Mingliang
Zhang, Yuanzhe
Wang, Yining
Finlayson, Neil
Bi, Renzhe
Henderson, Robert K.
Yuan, Zhen
Li, David Day-Uei
Instrumentation and Detectors
Medical Physics
Diffuse correlation spectroscopy (DCS) is a noninvasive optical technique that probes microvascular blood flow in deep tissues. Here, we present and validate a new on-chip hardware correlator for high-speed DCS measurements. The correlator is embedded in a custom-built 512 x 512 single-photon avalanche diode (SPAD) array named ATLAS, which computes intensity autocorrelation functions directly on-chip at a sampling rate of 116 Hz - the fastest DCS acquisition reported to date. Unlike conventional DCS systems that suffer from low light throughput and therefore cannot resolve cardiac pulsations at source-detector separations (rho) beyond 30 mm, our massively parallel on-chip architecture computes autocorrelations within each macropixel, eliminating the data-throughput bottleneck. This enables high-SNR, real-time detection of pulsatile blood flow even at rho = 50 mm on the human forehead. In phantom experiments at rho = 25 mm, ATLAS-DCS achieves a 12-fold improvement in signal-to-noise ratio over a conventional single-channel DCS instrument while operating at 116 Hz. In human subjects, we resolve functional hyperemia during a mental arithmetic task at rho = 30 mm. Furthermore, we integrate ATLAS DCS with a frequency-domain near-infrared spectroscopy (FD-NIRS) module, enabling simultaneous monitoring of blood flow and tissue oxygenation. With this combined system, we can concurrently resolve core hemodynamic parameters. The on-chip parallelized DCS design substantially improves detection speed, depth sensitivity, and real-time capability, paving the way for wearable, high-speed cerebral blood flow monitoring in both clinical and research settings.
title Real-time diffuse correlation spectroscopy with a chip-based correlator for measuring human cerebral blood flow and brain function
topic Instrumentation and Detectors
Medical Physics
url https://arxiv.org/abs/2503.17459