Cystic Lung Phantom to Validate Clinical CT Protocols

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Shah, Shefra, Hussaini, Farah, Mazilu, Dumitru, Bennett, Eric E., Wen, Han
Format: Preprint
Published: 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866917967997960192
author Shah, Shefra
Hussaini, Farah
Mazilu, Dumitru
Bennett, Eric E.
Wen, Han
author_facet Shah, Shefra
Hussaini, Farah
Mazilu, Dumitru
Bennett, Eric E.
Wen, Han
contents In CT-based evaluation of the extent of cystic changes in the lungs of patients with cystic lung diseases, such as Lymphangioleiomyomatosis (LAM), there is a lack of a lung phantom containing air-filled cavities that mimic pulmonary cysts to calibrate the measurement of cystic volumes from CT scans. Here we describe a simple, easy-to-replicate cystic lung phantom consisting of basic structures of a trachea and two lung compartments. The lung compartments contain air cavities of varying sizes to mimic cystic lesions. The lung volumes are equal to those of typical adults. The lung compartments are made of a foam material recommended by NIST to simulate the radiodensity of human lung parenchyma. In tests performed on a clinical scanner using two types of lung analysis software, the various structures in the lung phantom were correctly recognized by the software. The re-sulting cystic volume measurements revealed the relationship between the size of the cysts and the accuracy of the measurement. A significant finding is that the volumes of individual cysts were underestimated for small cysts. The error increased with decreasing cyst sizes. Such underestimation has not been mentioned previously and de-serves the attention of clinicians using CT scans to assess the cyst burden in the lungs, particularly in patients presenting with numerous small pulmonary cysts.
format Preprint
id arxiv_https___arxiv_org_abs_2503_19747
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Cystic Lung Phantom to Validate Clinical CT Protocols
Shah, Shefra
Hussaini, Farah
Mazilu, Dumitru
Bennett, Eric E.
Wen, Han
Medical Physics
In CT-based evaluation of the extent of cystic changes in the lungs of patients with cystic lung diseases, such as Lymphangioleiomyomatosis (LAM), there is a lack of a lung phantom containing air-filled cavities that mimic pulmonary cysts to calibrate the measurement of cystic volumes from CT scans. Here we describe a simple, easy-to-replicate cystic lung phantom consisting of basic structures of a trachea and two lung compartments. The lung compartments contain air cavities of varying sizes to mimic cystic lesions. The lung volumes are equal to those of typical adults. The lung compartments are made of a foam material recommended by NIST to simulate the radiodensity of human lung parenchyma. In tests performed on a clinical scanner using two types of lung analysis software, the various structures in the lung phantom were correctly recognized by the software. The re-sulting cystic volume measurements revealed the relationship between the size of the cysts and the accuracy of the measurement. A significant finding is that the volumes of individual cysts were underestimated for small cysts. The error increased with decreasing cyst sizes. Such underestimation has not been mentioned previously and de-serves the attention of clinicians using CT scans to assess the cyst burden in the lungs, particularly in patients presenting with numerous small pulmonary cysts.
title Cystic Lung Phantom to Validate Clinical CT Protocols
topic Medical Physics
url https://arxiv.org/abs/2503.19747