Development and Characterization of a High-Resolution and High-Sensitivity Collinear Resonance Ionization Spectroscopy Setup

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Hu, H. R., Guo, Y. F., Yang, X. F., Yan, Z., Mei, W. C., Chen, S. J., Liu, Y. S., Zhang, P., Bai, S. W., Chen, D. Y., Liu, Y. C., Wang, S. J., Li, Q. T., Ye, Y. L., He, C. Y., Yang, J., Liu, Z. Y.
Natura: Preprint
Pubblicazione: 2025
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866908373223473152
author Hu, H. R.
Guo, Y. F.
Yang, X. F.
Yan, Z.
Mei, W. C.
Chen, S. J.
Liu, Y. S.
Zhang, P.
Bai, S. W.
Chen, D. Y.
Liu, Y. C.
Wang, S. J.
Li, Q. T.
Ye, Y. L.
He, C. Y.
Yang, J.
Liu, Z. Y.
author_facet Hu, H. R.
Guo, Y. F.
Yang, X. F.
Yan, Z.
Mei, W. C.
Chen, S. J.
Liu, Y. S.
Zhang, P.
Bai, S. W.
Chen, D. Y.
Liu, Y. C.
Wang, S. J.
Li, Q. T.
Ye, Y. L.
He, C. Y.
Yang, J.
Liu, Z. Y.
contents With the recent implementation of a radio-frequency quadrupole (RFQ) cooler-buncher and a multi-step laser resonance ionization technique, our previously developed collinear laser spectroscopy setup has been successfully upgraded into a fully functional collinear resonance ionization spectroscopy system. The new system was fully characterized using a bunched ion beam at 30~keV, during which hyperfine structure spectra of $^{85,87}$Rb isotopes were measured. An overall efficiency exceeding 1:200 (one resonant ion detected for every 200 ions after the RFQ cooler-buncher) was achieved while maintaining a spectral resolution of 100 MHz. Under these conditions, the extracted hyperfine structure parameters and isotope shift for $^{85,87}$Rb show excellent agreement with the literature values. These results demonstrate the system's capability to perform high-resolution and high-sensitivity laser spectroscopy of neutron-rich Rb isotopes, which are expected to be produced at the Beijing Radioactive Ion-beam Facility at a rate of approximately 100 particles per second.
format Preprint
id arxiv_https___arxiv_org_abs_2503_20637
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Development and Characterization of a High-Resolution and High-Sensitivity Collinear Resonance Ionization Spectroscopy Setup
Hu, H. R.
Guo, Y. F.
Yang, X. F.
Yan, Z.
Mei, W. C.
Chen, S. J.
Liu, Y. S.
Zhang, P.
Bai, S. W.
Chen, D. Y.
Liu, Y. C.
Wang, S. J.
Li, Q. T.
Ye, Y. L.
He, C. Y.
Yang, J.
Liu, Z. Y.
Instrumentation and Detectors
Nuclear Experiment
Accelerator Physics
With the recent implementation of a radio-frequency quadrupole (RFQ) cooler-buncher and a multi-step laser resonance ionization technique, our previously developed collinear laser spectroscopy setup has been successfully upgraded into a fully functional collinear resonance ionization spectroscopy system. The new system was fully characterized using a bunched ion beam at 30~keV, during which hyperfine structure spectra of $^{85,87}$Rb isotopes were measured. An overall efficiency exceeding 1:200 (one resonant ion detected for every 200 ions after the RFQ cooler-buncher) was achieved while maintaining a spectral resolution of 100 MHz. Under these conditions, the extracted hyperfine structure parameters and isotope shift for $^{85,87}$Rb show excellent agreement with the literature values. These results demonstrate the system's capability to perform high-resolution and high-sensitivity laser spectroscopy of neutron-rich Rb isotopes, which are expected to be produced at the Beijing Radioactive Ion-beam Facility at a rate of approximately 100 particles per second.
title Development and Characterization of a High-Resolution and High-Sensitivity Collinear Resonance Ionization Spectroscopy Setup
topic Instrumentation and Detectors
Nuclear Experiment
Accelerator Physics
url https://arxiv.org/abs/2503.20637