contents Pulmonary embolism (PE) registries accelerate practice-improving research but depend on resource-intensive manual abstraction of radiology reports. We evaluated whether openly available large-language models (LLMs) can automate concept extraction from computed-tomography PE (CTPE) reports without sacrificing data quality. Four Llama-3 (L3) variants (3.0 8 B, 3.1 8 B, 3.1 70 B, 3.3 70 B) and two reviewer models Phi-4 (P4) 14 B and Gemma-3 27 B (G3) were tested on 250 dual-annotated CTPE reports each from MIMIC-IV and Duke University. Outcomes were accuracy, positive predictive value (PPV), and negative predictive value (NPV) versus a human gold standard across model sizes, temperature settings, and shot counts. Mean accuracy across all concepts increased with scale: 0.83 (L3-0 8 B), 0.91 (L3-1 8 B), and 0.96 for both 70 B variants; P4 14 B achieved 0.98; G3 matched. Accuracy differed by < 0.03 between datasets, underscoring external robustness. In dual-model concordance analysis (L3 70 B + P4 14 B), PE-presence PPV was >= 0.95 and NPV >= 0.98, while location, thrombus burden, right-heart strain, and image-quality artifacts each maintained PPV >= 0.90 and NPV >= 0.95. Fewer than 4% of individual concept annotations were discordant, and complete agreement was observed in more than 75% of reports. G3 performed comparably. LLMs therefore offer a scalable, accurate solution for PE registry abstraction, and a dual-model review workflow can further safeguard data quality with minimal human oversight.
format Preprint
id arxiv_https___arxiv_org_abs_2503_21004
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Evaluating Large Language Models for Automated Clinical Abstraction in Pulmonary Embolism Registries: Performance Across Model Sizes, Versions, and Parameters
Alwakeel, Mahmoud
Buck, Emory
Martin, Jonathan G.
Aslam, Imran
Rajagopal, Sudarshan
Pei, Jian
Podgoreanu, Mihai V.
Lindsell, Christopher J.
Wong, An-Kwok Ian
Computation and Language
Pulmonary embolism (PE) registries accelerate practice-improving research but depend on resource-intensive manual abstraction of radiology reports. We evaluated whether openly available large-language models (LLMs) can automate concept extraction from computed-tomography PE (CTPE) reports without sacrificing data quality. Four Llama-3 (L3) variants (3.0 8 B, 3.1 8 B, 3.1 70 B, 3.3 70 B) and two reviewer models Phi-4 (P4) 14 B and Gemma-3 27 B (G3) were tested on 250 dual-annotated CTPE reports each from MIMIC-IV and Duke University. Outcomes were accuracy, positive predictive value (PPV), and negative predictive value (NPV) versus a human gold standard across model sizes, temperature settings, and shot counts. Mean accuracy across all concepts increased with scale: 0.83 (L3-0 8 B), 0.91 (L3-1 8 B), and 0.96 for both 70 B variants; P4 14 B achieved 0.98; G3 matched. Accuracy differed by < 0.03 between datasets, underscoring external robustness. In dual-model concordance analysis (L3 70 B + P4 14 B), PE-presence PPV was >= 0.95 and NPV >= 0.98, while location, thrombus burden, right-heart strain, and image-quality artifacts each maintained PPV >= 0.90 and NPV >= 0.95. Fewer than 4% of individual concept annotations were discordant, and complete agreement was observed in more than 75% of reports. G3 performed comparably. LLMs therefore offer a scalable, accurate solution for PE registry abstraction, and a dual-model review workflow can further safeguard data quality with minimal human oversight.
title Evaluating Large Language Models for Automated Clinical Abstraction in Pulmonary Embolism Registries: Performance Across Model Sizes, Versions, and Parameters
topic Computation and Language
url https://arxiv.org/abs/2503.21004