Terahertz frequency-domain 4x4 Mueller matrix ellipsometer instrument designed for high-frequency magnetic resonance measurements

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Rindert, Viktor, Ruder, Alexander, Richter, Steffen, Kühne, Philipp, Bauer, Mark, Darakchieva, Vanya, Schubert, Mathias
Format: Preprint
Published: 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866916665115017216
author Rindert, Viktor
Ruder, Alexander
Richter, Steffen
Kühne, Philipp
Bauer, Mark
Darakchieva, Vanya
Schubert, Mathias
author_facet Rindert, Viktor
Ruder, Alexander
Richter, Steffen
Kühne, Philipp
Bauer, Mark
Darakchieva, Vanya
Schubert, Mathias
contents We report a Mueller matrix ellipsometer design using dual continuously rotating anisotropic meta wave plates which determines the full set of Mueller matrix elements in the terahertz spectral range. The instrument operates in the frequency domain and employs a frequency tunable, solid state synthesizer based, continuous wave terahertz source with sub-MHz bandwidth. The implemented source permits operation within 82-125 GHz and 170-250 GHz, without and with an additional frequency doubler, respectively. The terahertz transparent meta wave plates consist of 3D-printed polymer based columnar thin film structures with subwavelength dimensions. The rotating wave plates produce sufficient modulation of the Stokes vector components of transmitted terahertz light to use the wave plates in polarization state generator and polarization state detector devices. Fast terahertz light detection rate of a quasi optical solid state detector permits acquisition with few microsecond temporal resolution and electronic sweeping control of the source frequency. We develop a fast frequency sweeping scheme while continuously rotating the terahertz wave plates. Subsequent sorting of measured data permits measurements of Mueller matrix elements at hundreds of different wavelengths. The Mueller matrix elements are obtained by forward numerical reduction of the measured data using an algorithm developed by Ruder et al.[Opt. Lett. 45, 3541 (2020)]. The instrument is combined with a magnetocryostat capable of reaching magnetic field strengths at the sample position of -8 T...8 T and sample temperatures from 4 K...400 K. Hence, the instrument is suitable to measure the full Mueller matrix of samples with magnetic resonances as demonstrated recently by Rindert et al. [Phys. Rev. B 110, 054413 (2024)]. We discuss design, calibration, and example applications.
format Preprint
id arxiv_https___arxiv_org_abs_2503_22500
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Terahertz frequency-domain 4x4 Mueller matrix ellipsometer instrument designed for high-frequency magnetic resonance measurements
Rindert, Viktor
Ruder, Alexander
Richter, Steffen
Kühne, Philipp
Bauer, Mark
Darakchieva, Vanya
Schubert, Mathias
Instrumentation and Detectors
Materials Science
Optics
We report a Mueller matrix ellipsometer design using dual continuously rotating anisotropic meta wave plates which determines the full set of Mueller matrix elements in the terahertz spectral range. The instrument operates in the frequency domain and employs a frequency tunable, solid state synthesizer based, continuous wave terahertz source with sub-MHz bandwidth. The implemented source permits operation within 82-125 GHz and 170-250 GHz, without and with an additional frequency doubler, respectively. The terahertz transparent meta wave plates consist of 3D-printed polymer based columnar thin film structures with subwavelength dimensions. The rotating wave plates produce sufficient modulation of the Stokes vector components of transmitted terahertz light to use the wave plates in polarization state generator and polarization state detector devices. Fast terahertz light detection rate of a quasi optical solid state detector permits acquisition with few microsecond temporal resolution and electronic sweeping control of the source frequency. We develop a fast frequency sweeping scheme while continuously rotating the terahertz wave plates. Subsequent sorting of measured data permits measurements of Mueller matrix elements at hundreds of different wavelengths. The Mueller matrix elements are obtained by forward numerical reduction of the measured data using an algorithm developed by Ruder et al.[Opt. Lett. 45, 3541 (2020)]. The instrument is combined with a magnetocryostat capable of reaching magnetic field strengths at the sample position of -8 T...8 T and sample temperatures from 4 K...400 K. Hence, the instrument is suitable to measure the full Mueller matrix of samples with magnetic resonances as demonstrated recently by Rindert et al. [Phys. Rev. B 110, 054413 (2024)]. We discuss design, calibration, and example applications.
title Terahertz frequency-domain 4x4 Mueller matrix ellipsometer instrument designed for high-frequency magnetic resonance measurements
topic Instrumentation and Detectors
Materials Science
Optics
url https://arxiv.org/abs/2503.22500