contents This paper proposes a practical startup strategy for current source inverter (CSI)-fed Permanent Magnet Synchronous Motor (PMSM) drives in submersible pump applications, focusing on ensuring a seamless shift to sensorless field-oriented control (FOC). The method effectively manages the transition to sensorless operation without requiring precise current or alignment error calculations, thereby simplifying implementation. By addressing speed and current oscillations directly during the startup and transition stages, the approach significantly enhances overall system stability and responsiveness. Validation through simulation and experimental testing demonstrates the strategy's success in maintaining low oscillation levels across various operating conditions, confirming its reliability for high-performance industrial applications.
format Preprint
id arxiv_https___arxiv_org_abs_2503_22855
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Sensorless Field Oriented Control of CSI-Fed PMSM Drives Used in Submersible Pumps
Bahrami-Fard, Milad
Korrani, Majid Ghasemi
Fahimi, Babak
Systems and Control
This paper proposes a practical startup strategy for current source inverter (CSI)-fed Permanent Magnet Synchronous Motor (PMSM) drives in submersible pump applications, focusing on ensuring a seamless shift to sensorless field-oriented control (FOC). The method effectively manages the transition to sensorless operation without requiring precise current or alignment error calculations, thereby simplifying implementation. By addressing speed and current oscillations directly during the startup and transition stages, the approach significantly enhances overall system stability and responsiveness. Validation through simulation and experimental testing demonstrates the strategy's success in maintaining low oscillation levels across various operating conditions, confirming its reliability for high-performance industrial applications.
title Sensorless Field Oriented Control of CSI-Fed PMSM Drives Used in Submersible Pumps
topic Systems and Control
url https://arxiv.org/abs/2503.22855