Reducing Artifacts in Grating Interferometry Using Multiple Harmonics and Phase Step Corrections

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Meyer, Hunter C., Dooley, Conner B., Fontenot, Victoria L., Ham, Kyungmin, Butler, Leslie G., Noel, Alexandra, Dey, Joyoni
Formato: Preprint
Publicado: 2025
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866917971873497088
author Meyer, Hunter C.
Dooley, Conner B.
Fontenot, Victoria L.
Ham, Kyungmin
Butler, Leslie G.
Noel, Alexandra
Dey, Joyoni
author_facet Meyer, Hunter C.
Dooley, Conner B.
Fontenot, Victoria L.
Ham, Kyungmin
Butler, Leslie G.
Noel, Alexandra
Dey, Joyoni
contents X-ray interferometry is an emerging imaging modality with a wide variety of potential clinical applications, including lung and breast imaging, as well as in non-destructive testing, such as additive manufacturing and porosimetry. A grating interferometer uses a diffraction grating to produce a periodic interference pattern and measures how a patient or sample perturbs the pattern, producing three unique images that highlight X-ray absorption, refraction, and small angle scattering, known as the transmission, differential-phase, and dark-field images, respectively. Image artifacts that are unique to X-ray interferometry are introduced when assuming the fringe pattern is perfectly sinusoidal and the phase steps are evenly spaced. Inaccuracies in grating position, coupled with multi-harmonic fringes, lead to remnant oscillations and phase wraparound artifacts. We have developed an image recovery algorithm that uses additional harmonics, direct relative phase fitting, and phase step corrections to prevent them. The direct relative phase fitting removes the phase wraparound artifact. Correcting the phase step positions and introducing the additional harmonic removes the grating remnant artifact present in the transmission, differential-phase, and dark-field images. By modifying existing algorithms, the fit to the fringe pattern is greatly improved and artifacts are minimized, as we demonstrate with the imaging of several samples, including PMMA microspheres, ex vivo formalin fixed mouse lungs, and porous alumina.
format Preprint
id arxiv_https___arxiv_org_abs_2503_23148
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Reducing Artifacts in Grating Interferometry Using Multiple Harmonics and Phase Step Corrections
Meyer, Hunter C.
Dooley, Conner B.
Fontenot, Victoria L.
Ham, Kyungmin
Butler, Leslie G.
Noel, Alexandra
Dey, Joyoni
Optics
Image and Video Processing
Medical Physics
X-ray interferometry is an emerging imaging modality with a wide variety of potential clinical applications, including lung and breast imaging, as well as in non-destructive testing, such as additive manufacturing and porosimetry. A grating interferometer uses a diffraction grating to produce a periodic interference pattern and measures how a patient or sample perturbs the pattern, producing three unique images that highlight X-ray absorption, refraction, and small angle scattering, known as the transmission, differential-phase, and dark-field images, respectively. Image artifacts that are unique to X-ray interferometry are introduced when assuming the fringe pattern is perfectly sinusoidal and the phase steps are evenly spaced. Inaccuracies in grating position, coupled with multi-harmonic fringes, lead to remnant oscillations and phase wraparound artifacts. We have developed an image recovery algorithm that uses additional harmonics, direct relative phase fitting, and phase step corrections to prevent them. The direct relative phase fitting removes the phase wraparound artifact. Correcting the phase step positions and introducing the additional harmonic removes the grating remnant artifact present in the transmission, differential-phase, and dark-field images. By modifying existing algorithms, the fit to the fringe pattern is greatly improved and artifacts are minimized, as we demonstrate with the imaging of several samples, including PMMA microspheres, ex vivo formalin fixed mouse lungs, and porous alumina.
title Reducing Artifacts in Grating Interferometry Using Multiple Harmonics and Phase Step Corrections
topic Optics
Image and Video Processing
Medical Physics
url https://arxiv.org/abs/2503.23148