Expected performance of the ALPIDE pixel layers in ALICE FoCal

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Yi, Jie, Rauch, Max Philip
Format: Preprint
Publié: 2025
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866912308149616640
author Yi, Jie
Rauch, Max Philip
author_facet Yi, Jie
Rauch, Max Philip
contents The ALICE experiment is designed to study ultra-relativistic heavy-ion collisions at the Large Hadron Collider (LHC). As part of its major upgrades for Run 4, the Forward Calorimeter (FoCal) will be installed during Long Shutdown 3 (LS3). FoCal enables precise measurements of direct photon production at forward rapidity, providing a sensitive probe of the gluon distribution in protons and nuclei. This paper introduces the expected performance of the forward electromagnetic calorimeter (FoCal-E) and presents several potential strategies for mitigating occupancy and BUSY violation challenges in the pixel layers of FoCal-E. Beam test results demonstrate that back biasing effectively reduces pixel occupancy. Meanwhile, SystemC simulations explore additional mitigation strategies-such as grid masking and a regional trigger-to further minimize BUSY violations and enhance detector performance under high-luminosity conditions.
format Preprint
id arxiv_https___arxiv_org_abs_2504_03018
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Expected performance of the ALPIDE pixel layers in ALICE FoCal
Yi, Jie
Rauch, Max Philip
Instrumentation and Detectors
High Energy Physics - Experiment
The ALICE experiment is designed to study ultra-relativistic heavy-ion collisions at the Large Hadron Collider (LHC). As part of its major upgrades for Run 4, the Forward Calorimeter (FoCal) will be installed during Long Shutdown 3 (LS3). FoCal enables precise measurements of direct photon production at forward rapidity, providing a sensitive probe of the gluon distribution in protons and nuclei. This paper introduces the expected performance of the forward electromagnetic calorimeter (FoCal-E) and presents several potential strategies for mitigating occupancy and BUSY violation challenges in the pixel layers of FoCal-E. Beam test results demonstrate that back biasing effectively reduces pixel occupancy. Meanwhile, SystemC simulations explore additional mitigation strategies-such as grid masking and a regional trigger-to further minimize BUSY violations and enhance detector performance under high-luminosity conditions.
title Expected performance of the ALPIDE pixel layers in ALICE FoCal
topic Instrumentation and Detectors
High Energy Physics - Experiment
url https://arxiv.org/abs/2504.03018