Generative Large Language Models Trained for Detecting Errors in Radiology Reports

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Sun, Cong, Teichman, Kurt, Zhou, Yiliang, Critelli, Brian, Nauheim, David, Keir, Graham, Wang, Xindi, Zhong, Judy, Flanders, Adam E, Shih, George, Peng, Yifan
Format: Preprint
Publié: 2025
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866908304211443712
author Sun, Cong
Teichman, Kurt
Zhou, Yiliang
Critelli, Brian
Nauheim, David
Keir, Graham
Wang, Xindi
Zhong, Judy
Flanders, Adam E
Shih, George
Peng, Yifan
author_facet Sun, Cong
Teichman, Kurt
Zhou, Yiliang
Critelli, Brian
Nauheim, David
Keir, Graham
Wang, Xindi
Zhong, Judy
Flanders, Adam E
Shih, George
Peng, Yifan
contents In this retrospective study, a dataset was constructed with two parts. The first part included 1,656 synthetic chest radiology reports generated by GPT-4 using specified prompts, with 828 being error-free synthetic reports and 828 containing errors. The second part included 614 reports: 307 error-free reports between 2011 and 2016 from the MIMIC-CXR database and 307 corresponding synthetic reports with errors generated by GPT-4 on the basis of these MIMIC-CXR reports and specified prompts. All errors were categorized into four types: negation, left/right, interval change, and transcription errors. Then, several models, including Llama-3, GPT-4, and BiomedBERT, were refined using zero-shot prompting, few-shot prompting, or fine-tuning strategies. Finally, the performance of these models was evaluated using the F1 score, 95\% confidence interval (CI) and paired-sample t-tests on our constructed dataset, with the prediction results further assessed by radiologists. Using zero-shot prompting, the fine-tuned Llama-3-70B-Instruct model achieved the best performance with the following F1 scores: 0.769 for negation errors, 0.772 for left/right errors, 0.750 for interval change errors, 0.828 for transcription errors, and 0.780 overall. In the real-world evaluation phase, two radiologists reviewed 200 randomly selected reports output by the model. Of these, 99 were confirmed to contain errors detected by the models by both radiologists, and 163 were confirmed to contain model-detected errors by at least one radiologist. Generative LLMs, fine-tuned on synthetic and MIMIC-CXR radiology reports, greatly enhanced error detection in radiology reports.
format Preprint
id arxiv_https___arxiv_org_abs_2504_04336
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Generative Large Language Models Trained for Detecting Errors in Radiology Reports
Sun, Cong
Teichman, Kurt
Zhou, Yiliang
Critelli, Brian
Nauheim, David
Keir, Graham
Wang, Xindi
Zhong, Judy
Flanders, Adam E
Shih, George
Peng, Yifan
Computation and Language
Artificial Intelligence
In this retrospective study, a dataset was constructed with two parts. The first part included 1,656 synthetic chest radiology reports generated by GPT-4 using specified prompts, with 828 being error-free synthetic reports and 828 containing errors. The second part included 614 reports: 307 error-free reports between 2011 and 2016 from the MIMIC-CXR database and 307 corresponding synthetic reports with errors generated by GPT-4 on the basis of these MIMIC-CXR reports and specified prompts. All errors were categorized into four types: negation, left/right, interval change, and transcription errors. Then, several models, including Llama-3, GPT-4, and BiomedBERT, were refined using zero-shot prompting, few-shot prompting, or fine-tuning strategies. Finally, the performance of these models was evaluated using the F1 score, 95\% confidence interval (CI) and paired-sample t-tests on our constructed dataset, with the prediction results further assessed by radiologists. Using zero-shot prompting, the fine-tuned Llama-3-70B-Instruct model achieved the best performance with the following F1 scores: 0.769 for negation errors, 0.772 for left/right errors, 0.750 for interval change errors, 0.828 for transcription errors, and 0.780 overall. In the real-world evaluation phase, two radiologists reviewed 200 randomly selected reports output by the model. Of these, 99 were confirmed to contain errors detected by the models by both radiologists, and 163 were confirmed to contain model-detected errors by at least one radiologist. Generative LLMs, fine-tuned on synthetic and MIMIC-CXR radiology reports, greatly enhanced error detection in radiology reports.
title Generative Large Language Models Trained for Detecting Errors in Radiology Reports
topic Computation and Language
Artificial Intelligence
url https://arxiv.org/abs/2504.04336