Reliability Assessment of Low-Cost PM Sensors under High Humidity and High PM Level Outdoor Conditions

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Kumar, Gulshan, D, Prasannaa Kumar, Dhariwal, Jay, Srirangarajan, Seshan
Formato: Preprint
Publicado: 2025
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866912317599383552
author Kumar, Gulshan
D, Prasannaa Kumar
Dhariwal, Jay
Srirangarajan, Seshan
author_facet Kumar, Gulshan
D, Prasannaa Kumar
Dhariwal, Jay
Srirangarajan, Seshan
contents Low-cost particulate matter (PM) sensors have become increasingly popular due to their compact size, low power consumption, and cost-effective installation and maintenance. While several studies have explored the effects of meteorological conditions and pollution exposure on low-cost sensor (LCS) performance, few have addressed the combined impact of high PM concentration and high humidity levels. In contrast to most evaluation studies, which generally report $\text{PM}_{2.5}$ levels below $150~μ\text{g/m}^3$, our study observed hourly average $\text{PM}_{2.5}$ concentrations ranging from $6-611~μ\text{g/m}^3$ (mean value of $137~μ\text{g/m}^3$), with relative humidity between $25-95\%$ (mean value of $72\%$), and temperature varying from $6-29^\circ$C (mean value of $16^\circ$C). We evaluate three LCS models (SPS30, PMS7003, HPMA115C0-004) in outdoor conditions during the winter season in New Delhi, India, deployed alongside a reference-grade beta attenuation monitor (BAM). The results indicate a strong correlation between LCS and BAM measurements (${R^2} > 90\%$). The RMSE increases with increasing PM concentration and humidity levels but the narrow $95\%$ confidence interval range of LCS as a function of the reference BAM suggests the importance of LCS in air pollution monitoring. Among the evaluated LCS models, SPS30 showed the highest overall accuracy. Overall, the study demonstrates that LCS can effectively monitor air quality in regions with high PM and high humidity levels, provided appropriate correction models are applied.
format Preprint
id arxiv_https___arxiv_org_abs_2504_06615
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Reliability Assessment of Low-Cost PM Sensors under High Humidity and High PM Level Outdoor Conditions
Kumar, Gulshan
D, Prasannaa Kumar
Dhariwal, Jay
Srirangarajan, Seshan
Systems and Control
Low-cost particulate matter (PM) sensors have become increasingly popular due to their compact size, low power consumption, and cost-effective installation and maintenance. While several studies have explored the effects of meteorological conditions and pollution exposure on low-cost sensor (LCS) performance, few have addressed the combined impact of high PM concentration and high humidity levels. In contrast to most evaluation studies, which generally report $\text{PM}_{2.5}$ levels below $150~μ\text{g/m}^3$, our study observed hourly average $\text{PM}_{2.5}$ concentrations ranging from $6-611~μ\text{g/m}^3$ (mean value of $137~μ\text{g/m}^3$), with relative humidity between $25-95\%$ (mean value of $72\%$), and temperature varying from $6-29^\circ$C (mean value of $16^\circ$C). We evaluate three LCS models (SPS30, PMS7003, HPMA115C0-004) in outdoor conditions during the winter season in New Delhi, India, deployed alongside a reference-grade beta attenuation monitor (BAM). The results indicate a strong correlation between LCS and BAM measurements (${R^2} > 90\%$). The RMSE increases with increasing PM concentration and humidity levels but the narrow $95\%$ confidence interval range of LCS as a function of the reference BAM suggests the importance of LCS in air pollution monitoring. Among the evaluated LCS models, SPS30 showed the highest overall accuracy. Overall, the study demonstrates that LCS can effectively monitor air quality in regions with high PM and high humidity levels, provided appropriate correction models are applied.
title Reliability Assessment of Low-Cost PM Sensors under High Humidity and High PM Level Outdoor Conditions
topic Systems and Control
url https://arxiv.org/abs/2504.06615