Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system
Fuente:
arXiv
Gespeichert in:
| Hauptverfasser: | , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , |
|---|---|
| Format: | Preprint |
| Veröffentlicht: |
2025
|
| Schlagworte: | |
| Online-Zugang: | |
| Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
| _version_ | 1866911097167020032 |
|---|---|
| author | nEXO Collaboration Anker, A. Breur, P. A. Mong, B. Acharya, P. Amy, A. Angelico, E. Arnquist, I. J. Atencio, A. Bane, J. Belov, V. Bernard, E. P. Bhatta, T. Bolotnikov, A. Breslin, J. Brodsky, J. P. Bron, S. Brown, E. Brunner, T. Burnell, B. Caden, E. Cao, L. Q. Cao, G. F. Cesmecioglu, D. Chernyak, D. Chiu, M. Collister, R. Daniels, T. Darroch, L. DeVoe, R. di Vacri, M. L. Ding, Y. Y. Dolinski, M. J. Dragone, A. Eckert, B. Elbeltagi, M. Emara, A. Fairbank, W. Fatemighomi, N. Foust, B. Fu, Y. S. Gallacher, D. Gallice, N. Giacomini, G. Gillis, W. Gorham, A. Gornea, R. Gratta, G. Guan, Y. D. Hardy, C. A. Hedges, S. Heffner, M. Hein, E. Holt, J. D. Iverson, A. Jiang, X. S. Karelin, A. Keblbeck, D. Kotov, I. Kuchenkov, A. Kumar, K. S. Larson, A. Latif, M. B. Leach, K. G. Lenardo, B. G. Lennarz, A. Leonard, D. S. Leung, K. Lewis, H. Li, G. Li, X. Li, Z. Licciardi, C. Lindsay, R. MacLellan, R. Majidi, S. Malbrunot, C. Marquis, M. Masbou, J. Medina-Peregrina, M. Mngonyama, S. Moore, D. C. Ngwadla, X. E. Ni, K. Nolan, A. Nowicki, S. C. Ondze, J. C. Nzobadila Odian, A. Orrell, J. L. Ortega, G. S. Overman, C. T. Pagani, L. Smalley, H. Peltz Perna, A. Piepke, A. Pocar, A. Radeka, V. Raguzin, E. Rai, R. Rasiwala, H. Ray, D. Rescia, S. Retiére, F. Richardson, G. Rocco, N. Ross, R. Rowson, P. C. Saldanha, R. Sangiorgio, S. Sekula, S. Shetty, T. Si, L. Spadoni, F. Stekhanov, V. Sun, X. L. Thibado, S. Totev, T. Triambak, S. Tsang, R. H. M. Tyuka, O. A. van Bruggen, E. Vidal, M. Viel, S. Walent, M. Wang, H. Wang, Q. D. Wang, Y. G. Watts, M. Wehrfritz, M. Wei, W. Wen, L. J. Wichoski, U. Wilde, S. Worcester, M. Wu, X. M. Xu, H. Yang, H. B. Yang, L. Yu, M. Zeldovich, O. Zhao, J. |
| author_facet | nEXO Collaboration Anker, A. Breur, P. A. Mong, B. Acharya, P. Amy, A. Angelico, E. Arnquist, I. J. Atencio, A. Bane, J. Belov, V. Bernard, E. P. Bhatta, T. Bolotnikov, A. Breslin, J. Brodsky, J. P. Bron, S. Brown, E. Brunner, T. Burnell, B. Caden, E. Cao, L. Q. Cao, G. F. Cesmecioglu, D. Chernyak, D. Chiu, M. Collister, R. Daniels, T. Darroch, L. DeVoe, R. di Vacri, M. L. Ding, Y. Y. Dolinski, M. J. Dragone, A. Eckert, B. Elbeltagi, M. Emara, A. Fairbank, W. Fatemighomi, N. Foust, B. Fu, Y. S. Gallacher, D. Gallice, N. Giacomini, G. Gillis, W. Gorham, A. Gornea, R. Gratta, G. Guan, Y. D. Hardy, C. A. Hedges, S. Heffner, M. Hein, E. Holt, J. D. Iverson, A. Jiang, X. S. Karelin, A. Keblbeck, D. Kotov, I. Kuchenkov, A. Kumar, K. S. Larson, A. Latif, M. B. Leach, K. G. Lenardo, B. G. Lennarz, A. Leonard, D. S. Leung, K. Lewis, H. Li, G. Li, X. Li, Z. Licciardi, C. Lindsay, R. MacLellan, R. Majidi, S. Malbrunot, C. Marquis, M. Masbou, J. Medina-Peregrina, M. Mngonyama, S. Moore, D. C. Ngwadla, X. E. Ni, K. Nolan, A. Nowicki, S. C. Ondze, J. C. Nzobadila Odian, A. Orrell, J. L. Ortega, G. S. Overman, C. T. Pagani, L. Smalley, H. Peltz Perna, A. Piepke, A. Pocar, A. Radeka, V. Raguzin, E. Rai, R. Rasiwala, H. Ray, D. Rescia, S. Retiére, F. Richardson, G. Rocco, N. Ross, R. Rowson, P. C. Saldanha, R. Sangiorgio, S. Sekula, S. Shetty, T. Si, L. Spadoni, F. Stekhanov, V. Sun, X. L. Thibado, S. Totev, T. Triambak, S. Tsang, R. H. M. Tyuka, O. A. van Bruggen, E. Vidal, M. Viel, S. Walent, M. Wang, H. Wang, Q. D. Wang, Y. G. Watts, M. Wehrfritz, M. Wei, W. Wen, L. J. Wichoski, U. Wilde, S. Worcester, M. Wu, X. M. Xu, H. Yang, H. B. Yang, L. Yu, M. Zeldovich, O. Zhao, J. |
| contents | Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 $μ$Bq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments. |
| format | Preprint |
| id |
arxiv_https___arxiv_org_abs_2504_15464 |
| institution | arXiv |
| publishDate | 2025 |
| record_format | arxiv |
| spellingShingle | Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system nEXO Collaboration Anker, A. Breur, P. A. Mong, B. Acharya, P. Amy, A. Angelico, E. Arnquist, I. J. Atencio, A. Bane, J. Belov, V. Bernard, E. P. Bhatta, T. Bolotnikov, A. Breslin, J. Brodsky, J. P. Bron, S. Brown, E. Brunner, T. Burnell, B. Caden, E. Cao, L. Q. Cao, G. F. Cesmecioglu, D. Chernyak, D. Chiu, M. Collister, R. Daniels, T. Darroch, L. DeVoe, R. di Vacri, M. L. Ding, Y. Y. Dolinski, M. J. Dragone, A. Eckert, B. Elbeltagi, M. Emara, A. Fairbank, W. Fatemighomi, N. Foust, B. Fu, Y. S. Gallacher, D. Gallice, N. Giacomini, G. Gillis, W. Gorham, A. Gornea, R. Gratta, G. Guan, Y. D. Hardy, C. A. Hedges, S. Heffner, M. Hein, E. Holt, J. D. Iverson, A. Jiang, X. S. Karelin, A. Keblbeck, D. Kotov, I. Kuchenkov, A. Kumar, K. S. Larson, A. Latif, M. B. Leach, K. G. Lenardo, B. G. Lennarz, A. Leonard, D. S. Leung, K. Lewis, H. Li, G. Li, X. Li, Z. Licciardi, C. Lindsay, R. MacLellan, R. Majidi, S. Malbrunot, C. Marquis, M. Masbou, J. Medina-Peregrina, M. Mngonyama, S. Moore, D. C. Ngwadla, X. E. Ni, K. Nolan, A. Nowicki, S. C. Ondze, J. C. Nzobadila Odian, A. Orrell, J. L. Ortega, G. S. Overman, C. T. Pagani, L. Smalley, H. Peltz Perna, A. Piepke, A. Pocar, A. Radeka, V. Raguzin, E. Rai, R. Rasiwala, H. Ray, D. Rescia, S. Retiére, F. Richardson, G. Rocco, N. Ross, R. Rowson, P. C. Saldanha, R. Sangiorgio, S. Sekula, S. Shetty, T. Si, L. Spadoni, F. Stekhanov, V. Sun, X. L. Thibado, S. Totev, T. Triambak, S. Tsang, R. H. M. Tyuka, O. A. van Bruggen, E. Vidal, M. Viel, S. Walent, M. Wang, H. Wang, Q. D. Wang, Y. G. Watts, M. Wehrfritz, M. Wei, W. Wen, L. J. Wichoski, U. Wilde, S. Worcester, M. Wu, X. M. Xu, H. Yang, H. B. Yang, L. Yu, M. Zeldovich, O. Zhao, J. Instrumentation and Detectors High Energy Physics - Experiment Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 $μ$Bq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments. |
| title | Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system |
| topic | Instrumentation and Detectors High Energy Physics - Experiment |
| url | https://arxiv.org/abs/2504.15464 |