Tendon-Actuated Concentric Tube Endonasal Robot (TACTER)

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Yamamoto, Kent K., Zachem, Tanner J., Kheradmand, Pejman, Zheng, Patrick, Abdelgadir, Jihad, Bailey, Jared Laurance, Pieter, Kaelyn, Codd, Patrick J., Chitalia, Yash
Format: Preprint
Published: 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866908621740179456
author Yamamoto, Kent K.
Zachem, Tanner J.
Kheradmand, Pejman
Zheng, Patrick
Abdelgadir, Jihad
Bailey, Jared Laurance
Pieter, Kaelyn
Codd, Patrick J.
Chitalia, Yash
author_facet Yamamoto, Kent K.
Zachem, Tanner J.
Kheradmand, Pejman
Zheng, Patrick
Abdelgadir, Jihad
Bailey, Jared Laurance
Pieter, Kaelyn
Codd, Patrick J.
Chitalia, Yash
contents Endoscopic endonasal approaches (EEA) have become more prevalent for minimally invasive skull base and sinus surgeries. However, rigid scopes and tools significantly decrease the surgeon's ability to operate in tight anatomical spaces and avoid critical structures such as the internal carotid artery and cranial nerves. This paper proposes a novel tendon-actuated concentric tube endonasal robot (TACTER) design in which two tendon-actuated robots are concentric to each other, resulting in an outer and inner robot that can bend independently. The outer robot is a unidirectionally asymmetric notch (UAN) nickel-titanium robot, and the inner robot is a 3D-printed bidirectional robot, with a nickel-titanium bending member. In addition, the inner robot can translate axially within the outer robot, allowing the tool to traverse through structures while bending, thereby executing follow-the-leader motion. A Cosserat-rod based mechanical model is proposed that uses tendon tension of both tendon-actuated robots and the relative translation between the robots as inputs and predicts the TACTER tip position for varying input parameters. The model is validated with experiments, and a human cadaver experiment is presented to demonstrate maneuverability from the nostril to the sphenoid sinus. This work presents the first tendon-actuated concentric tube (TACT) dexterous robotic tool capable of performing follow-the-leader motion within natural nasal orifices to cover workspaces typically required for a successful EEA.
format Preprint
id arxiv_https___arxiv_org_abs_2504_19948
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Tendon-Actuated Concentric Tube Endonasal Robot (TACTER)
Yamamoto, Kent K.
Zachem, Tanner J.
Kheradmand, Pejman
Zheng, Patrick
Abdelgadir, Jihad
Bailey, Jared Laurance
Pieter, Kaelyn
Codd, Patrick J.
Chitalia, Yash
Robotics
Endoscopic endonasal approaches (EEA) have become more prevalent for minimally invasive skull base and sinus surgeries. However, rigid scopes and tools significantly decrease the surgeon's ability to operate in tight anatomical spaces and avoid critical structures such as the internal carotid artery and cranial nerves. This paper proposes a novel tendon-actuated concentric tube endonasal robot (TACTER) design in which two tendon-actuated robots are concentric to each other, resulting in an outer and inner robot that can bend independently. The outer robot is a unidirectionally asymmetric notch (UAN) nickel-titanium robot, and the inner robot is a 3D-printed bidirectional robot, with a nickel-titanium bending member. In addition, the inner robot can translate axially within the outer robot, allowing the tool to traverse through structures while bending, thereby executing follow-the-leader motion. A Cosserat-rod based mechanical model is proposed that uses tendon tension of both tendon-actuated robots and the relative translation between the robots as inputs and predicts the TACTER tip position for varying input parameters. The model is validated with experiments, and a human cadaver experiment is presented to demonstrate maneuverability from the nostril to the sphenoid sinus. This work presents the first tendon-actuated concentric tube (TACT) dexterous robotic tool capable of performing follow-the-leader motion within natural nasal orifices to cover workspaces typically required for a successful EEA.
title Tendon-Actuated Concentric Tube Endonasal Robot (TACTER)
topic Robotics
url https://arxiv.org/abs/2504.19948