Saved in:
Bibliographic Details
Main Authors: Hardt, Jennifer J., Pryanichnikov, Alexander A., Jäkel, Oliver, Seco, Joao, Wahl, Niklas
Format: Preprint
Published: 2025
Subjects:
Online Access:https://arxiv.org/abs/2505.01165
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866911321001295872
author Hardt, Jennifer J.
Pryanichnikov, Alexander A.
Jäkel, Oliver
Seco, Joao
Wahl, Niklas
author_facet Hardt, Jennifer J.
Pryanichnikov, Alexander A.
Jäkel, Oliver
Seco, Joao
Wahl, Niklas
contents Background: Recently, mixed carbon-helium beams were proposed for range verification in carbon ion therapy: Helium, with three times the range of carbon, serves as an on-line range probe, and is mixed into a therapeutic carbon beam. Purpose: Treatment monitoring is of special interest for lung cancer therapy, however the helium range might not always be sufficient to exit the patient distally. Therefore mixed beam use cases of several patient sites are considered. Methods: An extension to the open-source planning toolkit, matRad allows for calculation and optimization of mixed beam treatment plans. The use of the mixed beam method in 15 patients with lung cancer, as well as in a prostate and liver case, for various potential beam configurations was investigated. Planning strategies to optimize the residual helium range considering the sensitive energy range of the imaging detector were developed. A strategy involves adding helium to energies whose range is sufficient. Another one is to use range shifters to increase the helium energy and thus range. Results: In most patient cases, the residual helium range of at least one spot is too low. All investigated planning strategies can be used to ensure a high enough helium range while still keeping a low helium dose and a satisfactory total mixed carbon-helium beam dose. The use of range shifters allows for the detection of more spots. Conclusion: The mixed beam method shows promising results for online motioning. The use of range shifters ensures a high enough helium range and more detectable spots, allowing for a wider-spread application.
format Preprint
id arxiv_https___arxiv_org_abs_2505_01165
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Helium Range Viability for Online Range Probing in Mixed Carbon-Helium Beams
Hardt, Jennifer J.
Pryanichnikov, Alexander A.
Jäkel, Oliver
Seco, Joao
Wahl, Niklas
Medical Physics
Background: Recently, mixed carbon-helium beams were proposed for range verification in carbon ion therapy: Helium, with three times the range of carbon, serves as an on-line range probe, and is mixed into a therapeutic carbon beam. Purpose: Treatment monitoring is of special interest for lung cancer therapy, however the helium range might not always be sufficient to exit the patient distally. Therefore mixed beam use cases of several patient sites are considered. Methods: An extension to the open-source planning toolkit, matRad allows for calculation and optimization of mixed beam treatment plans. The use of the mixed beam method in 15 patients with lung cancer, as well as in a prostate and liver case, for various potential beam configurations was investigated. Planning strategies to optimize the residual helium range considering the sensitive energy range of the imaging detector were developed. A strategy involves adding helium to energies whose range is sufficient. Another one is to use range shifters to increase the helium energy and thus range. Results: In most patient cases, the residual helium range of at least one spot is too low. All investigated planning strategies can be used to ensure a high enough helium range while still keeping a low helium dose and a satisfactory total mixed carbon-helium beam dose. The use of range shifters allows for the detection of more spots. Conclusion: The mixed beam method shows promising results for online motioning. The use of range shifters ensures a high enough helium range and more detectable spots, allowing for a wider-spread application.
title Helium Range Viability for Online Range Probing in Mixed Carbon-Helium Beams