Gamma-ray and high-energy X-ray detection with large area scintillating crystals: a hands-on review

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
1. Verfasser: Bonesini, M.
Format: Preprint
Veröffentlicht: 2025
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866916731836956672
author Bonesini, M.
author_facet Bonesini, M.
contents Detection of photons with scintillating inorganic crystals in the high-energy range (> 0.1 MeV) will be discussed, making a comparison with other available methods. Energy resolutions up to 2 % at 662 keV and fast decay time of the order of 20 ns are within reach, with the introduction of Ce-doped crystals instead of alkali halide ones. Development is underway for the production of non-hygroscopic scintillating crystals, such as PrLuAg and CE:GAAG. At the end of this review, examples of experimental devices based on scintillating inorganic crystals will be discussed. Practical hands-on experience is emphasized at the expense of a more comprehensive description of all available and possible options. Detectors' construction details and the consequences of the different choices will be discussed. Emphasis will be put on the LaBr3:Ce-based detectors that are the present ''golden standard'' in gamma ray spectroscopy. This review will focus on photon detection in the high-energy region: mainly 0.1-2 MeV, including both gamma rays and high-energy X-rays, even if many considerations may be applied to the detection of low-energy X-rays.
format Preprint
id arxiv_https___arxiv_org_abs_2505_06929
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Gamma-ray and high-energy X-ray detection with large area scintillating crystals: a hands-on review
Bonesini, M.
Instrumentation and Detectors
Atomic Physics
Detection of photons with scintillating inorganic crystals in the high-energy range (> 0.1 MeV) will be discussed, making a comparison with other available methods. Energy resolutions up to 2 % at 662 keV and fast decay time of the order of 20 ns are within reach, with the introduction of Ce-doped crystals instead of alkali halide ones. Development is underway for the production of non-hygroscopic scintillating crystals, such as PrLuAg and CE:GAAG. At the end of this review, examples of experimental devices based on scintillating inorganic crystals will be discussed. Practical hands-on experience is emphasized at the expense of a more comprehensive description of all available and possible options. Detectors' construction details and the consequences of the different choices will be discussed. Emphasis will be put on the LaBr3:Ce-based detectors that are the present ''golden standard'' in gamma ray spectroscopy. This review will focus on photon detection in the high-energy region: mainly 0.1-2 MeV, including both gamma rays and high-energy X-rays, even if many considerations may be applied to the detection of low-energy X-rays.
title Gamma-ray and high-energy X-ray detection with large area scintillating crystals: a hands-on review
topic Instrumentation and Detectors
Atomic Physics
url https://arxiv.org/abs/2505.06929