A flexible approach for fat-water separation with bipolar readouts and correction of gradient-induced phase and amplitude effects

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Pazmino, Jorge Campos, Bider, Renée-Claude, Fortier, Véronique, Levesque, Ives R.
Format: Preprint
Published: 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866909615732555776
author Pazmino, Jorge Campos
Bider, Renée-Claude
Fortier, Véronique
Levesque, Ives R.
author_facet Pazmino, Jorge Campos
Bider, Renée-Claude
Fortier, Véronique
Levesque, Ives R.
contents Purpose: To develop a fat-water separation approach that corrects bipolar readout gradient induced effects, without additional scans, that is compatible with any fat-water separation method. Theory and Methods: The proposed approach combines joint fat-water separation of the odd and even echoes of a bipolar multi-echo gradient echo acquisition with an inverse problem to find least-squares estimates for phase and amplitude corrections to eliminate bipolar-induced effects. Optimization of sequence parameter selection through the calculation of the number of signal averages (NSA) with Cramér-Rao Bound theory (CRB) is presented. The application of the proposed approach is demonstrated with a graph cut optimization and further characterization of the accuracy was performed via Monte Carlo Simulations (MC). The proposed approach was tested in phantoms and in vivo. Proton density fat fraction maps (PDFF) were evaluated to quantify performance. Results: NSA calculations suggest short TE1 and ΔTE=1.5 ms as optimal alternatives for fat-water separation. MC simulations demonstrated accurate estimation of fat and water complex signals, ψ, and R_2^* with mean relative error within 1%. In phantoms and in vivo, the proposed approach effectively eliminated effects induced by bipolar readout gradients, improving the outcome of the fat-water separation. Conclusion: We proposed an approach to correct bipolar readout-induced effects that are detrimental for fat-water separation. This approach can extend the use of existing fat-water separation techniques designed for data acquired using unipolar readout gradients to data collected with bipolar readout gradients.
format Preprint
id arxiv_https___arxiv_org_abs_2505_13015
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle A flexible approach for fat-water separation with bipolar readouts and correction of gradient-induced phase and amplitude effects
Pazmino, Jorge Campos
Bider, Renée-Claude
Fortier, Véronique
Levesque, Ives R.
Medical Physics
Purpose: To develop a fat-water separation approach that corrects bipolar readout gradient induced effects, without additional scans, that is compatible with any fat-water separation method. Theory and Methods: The proposed approach combines joint fat-water separation of the odd and even echoes of a bipolar multi-echo gradient echo acquisition with an inverse problem to find least-squares estimates for phase and amplitude corrections to eliminate bipolar-induced effects. Optimization of sequence parameter selection through the calculation of the number of signal averages (NSA) with Cramér-Rao Bound theory (CRB) is presented. The application of the proposed approach is demonstrated with a graph cut optimization and further characterization of the accuracy was performed via Monte Carlo Simulations (MC). The proposed approach was tested in phantoms and in vivo. Proton density fat fraction maps (PDFF) were evaluated to quantify performance. Results: NSA calculations suggest short TE1 and ΔTE=1.5 ms as optimal alternatives for fat-water separation. MC simulations demonstrated accurate estimation of fat and water complex signals, ψ, and R_2^* with mean relative error within 1%. In phantoms and in vivo, the proposed approach effectively eliminated effects induced by bipolar readout gradients, improving the outcome of the fat-water separation. Conclusion: We proposed an approach to correct bipolar readout-induced effects that are detrimental for fat-water separation. This approach can extend the use of existing fat-water separation techniques designed for data acquired using unipolar readout gradients to data collected with bipolar readout gradients.
title A flexible approach for fat-water separation with bipolar readouts and correction of gradient-induced phase and amplitude effects
topic Medical Physics
url https://arxiv.org/abs/2505.13015