NOVA: A Benchmark for Anomaly Localization and Clinical Reasoning in Brain MRI

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Bercea, Cosmin I., Li, Jun, Raffler, Philipp, Riedel, Evamaria O., Schmitzer, Lena, Kurz, Angela, Bitzer, Felix, Roßmüller, Paula, Canisius, Julian, Beyrle, Mirjam L., Liu, Che, Bai, Wenjia, Kainz, Bernhard, Schnabel, Julia A., Wiestler, Benedikt
Format: Preprint
Published: 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866913848184799232
author Bercea, Cosmin I.
Li, Jun
Raffler, Philipp
Riedel, Evamaria O.
Schmitzer, Lena
Kurz, Angela
Bitzer, Felix
Roßmüller, Paula
Canisius, Julian
Beyrle, Mirjam L.
Liu, Che
Bai, Wenjia
Kainz, Bernhard
Schnabel, Julia A.
Wiestler, Benedikt
author_facet Bercea, Cosmin I.
Li, Jun
Raffler, Philipp
Riedel, Evamaria O.
Schmitzer, Lena
Kurz, Angela
Bitzer, Felix
Roßmüller, Paula
Canisius, Julian
Beyrle, Mirjam L.
Liu, Che
Bai, Wenjia
Kainz, Bernhard
Schnabel, Julia A.
Wiestler, Benedikt
contents In many real-world applications, deployed models encounter inputs that differ from the data seen during training. Out-of-distribution detection identifies whether an input stems from an unseen distribution, while open-world recognition flags such inputs to ensure the system remains robust as ever-emerging, previously $unknown$ categories appear and must be addressed without retraining. Foundation and vision-language models are pre-trained on large and diverse datasets with the expectation of broad generalization across domains, including medical imaging. However, benchmarking these models on test sets with only a few common outlier types silently collapses the evaluation back to a closed-set problem, masking failures on rare or truly novel conditions encountered in clinical use. We therefore present $NOVA$, a challenging, real-life $evaluation-only$ benchmark of $\sim$900 brain MRI scans that span 281 rare pathologies and heterogeneous acquisition protocols. Each case includes rich clinical narratives and double-blinded expert bounding-box annotations. Together, these enable joint assessment of anomaly localisation, visual captioning, and diagnostic reasoning. Because NOVA is never used for training, it serves as an $extreme$ stress-test of out-of-distribution generalisation: models must bridge a distribution gap both in sample appearance and in semantic space. Baseline results with leading vision-language models (GPT-4o, Gemini 2.0 Flash, and Qwen2.5-VL-72B) reveal substantial performance drops across all tasks, establishing NOVA as a rigorous testbed for advancing models that can detect, localize, and reason about truly unknown anomalies.
format Preprint
id arxiv_https___arxiv_org_abs_2505_14064
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle NOVA: A Benchmark for Anomaly Localization and Clinical Reasoning in Brain MRI
Bercea, Cosmin I.
Li, Jun
Raffler, Philipp
Riedel, Evamaria O.
Schmitzer, Lena
Kurz, Angela
Bitzer, Felix
Roßmüller, Paula
Canisius, Julian
Beyrle, Mirjam L.
Liu, Che
Bai, Wenjia
Kainz, Bernhard
Schnabel, Julia A.
Wiestler, Benedikt
Image and Video Processing
Artificial Intelligence
Computer Vision and Pattern Recognition
Machine Learning
In many real-world applications, deployed models encounter inputs that differ from the data seen during training. Out-of-distribution detection identifies whether an input stems from an unseen distribution, while open-world recognition flags such inputs to ensure the system remains robust as ever-emerging, previously $unknown$ categories appear and must be addressed without retraining. Foundation and vision-language models are pre-trained on large and diverse datasets with the expectation of broad generalization across domains, including medical imaging. However, benchmarking these models on test sets with only a few common outlier types silently collapses the evaluation back to a closed-set problem, masking failures on rare or truly novel conditions encountered in clinical use. We therefore present $NOVA$, a challenging, real-life $evaluation-only$ benchmark of $\sim$900 brain MRI scans that span 281 rare pathologies and heterogeneous acquisition protocols. Each case includes rich clinical narratives and double-blinded expert bounding-box annotations. Together, these enable joint assessment of anomaly localisation, visual captioning, and diagnostic reasoning. Because NOVA is never used for training, it serves as an $extreme$ stress-test of out-of-distribution generalisation: models must bridge a distribution gap both in sample appearance and in semantic space. Baseline results with leading vision-language models (GPT-4o, Gemini 2.0 Flash, and Qwen2.5-VL-72B) reveal substantial performance drops across all tasks, establishing NOVA as a rigorous testbed for advancing models that can detect, localize, and reason about truly unknown anomalies.
title NOVA: A Benchmark for Anomaly Localization and Clinical Reasoning in Brain MRI
topic Image and Video Processing
Artificial Intelligence
Computer Vision and Pattern Recognition
Machine Learning
url https://arxiv.org/abs/2505.14064