Impact of Data Sparsity on Machine Learning for Fault Detection in Power System Protection

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Oelhaf, Julian, Kordowich, Georg, Kim, Changhun, Perez-Toro, Paula Andrea, Maier, Andreas, Jager, Johann, Bayer, Siming
Natura: Preprint
Pubblicazione: 2025
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866909965789167616
author Oelhaf, Julian
Kordowich, Georg
Kim, Changhun
Perez-Toro, Paula Andrea
Maier, Andreas
Jager, Johann
Bayer, Siming
author_facet Oelhaf, Julian
Kordowich, Georg
Kim, Changhun
Perez-Toro, Paula Andrea
Maier, Andreas
Jager, Johann
Bayer, Siming
contents Germany's transition to a renewable energy-based power system is reshaping grid operations, requiring advanced monitoring and control to manage decentralized generation. Machine learning (ML) has emerged as a powerful tool for power system protection, particularly for fault detection (FD) and fault line identification (FLI) in transmission grids. However, ML model reliability depends on data quality and availability. Data sparsity resulting from sensor failures, communication disruptions, or reduced sampling rates poses a challenge to ML-based FD and FLI. Yet, its impact has not been systematically validated prior to this work. In response, we propose a framework to assess the impact of data sparsity on ML-based FD and FLI performance. We simulate realistic data sparsity scenarios, evaluate their impact, derive quantitative insights, and demonstrate the effectiveness of this evaluation strategy by applying it to an existing ML-based framework. Results show the ML model remains robust for FD, maintaining an F1-score of 0.999 $\pm$ 0.000 even after a 50x data reduction. In contrast, FLI is more sensitive, with performance decreasing by 55.61% for missing voltage measurements and 9.73% due to communication failures at critical network points. These findings offer actionable insights for optimizing ML models for real-world grid protection. This enables more efficient FD and supports targeted improvements in FLI.
format Preprint
id arxiv_https___arxiv_org_abs_2505_15560
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Impact of Data Sparsity on Machine Learning for Fault Detection in Power System Protection
Oelhaf, Julian
Kordowich, Georg
Kim, Changhun
Perez-Toro, Paula Andrea
Maier, Andreas
Jager, Johann
Bayer, Siming
Machine Learning
Signal Processing
Germany's transition to a renewable energy-based power system is reshaping grid operations, requiring advanced monitoring and control to manage decentralized generation. Machine learning (ML) has emerged as a powerful tool for power system protection, particularly for fault detection (FD) and fault line identification (FLI) in transmission grids. However, ML model reliability depends on data quality and availability. Data sparsity resulting from sensor failures, communication disruptions, or reduced sampling rates poses a challenge to ML-based FD and FLI. Yet, its impact has not been systematically validated prior to this work. In response, we propose a framework to assess the impact of data sparsity on ML-based FD and FLI performance. We simulate realistic data sparsity scenarios, evaluate their impact, derive quantitative insights, and demonstrate the effectiveness of this evaluation strategy by applying it to an existing ML-based framework. Results show the ML model remains robust for FD, maintaining an F1-score of 0.999 $\pm$ 0.000 even after a 50x data reduction. In contrast, FLI is more sensitive, with performance decreasing by 55.61% for missing voltage measurements and 9.73% due to communication failures at critical network points. These findings offer actionable insights for optimizing ML models for real-world grid protection. This enables more efficient FD and supports targeted improvements in FLI.
title Impact of Data Sparsity on Machine Learning for Fault Detection in Power System Protection
topic Machine Learning
Signal Processing
url https://arxiv.org/abs/2505.15560