AFIRE: Accurate and Fast Image Reconstruction Algorithm for Geometric-inconsistent Multispectral CT

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Gao, Yu, Chen, Chong
Format: Preprint
Published: 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866913959537278976
author Gao, Yu
Chen, Chong
author_facet Gao, Yu
Chen, Chong
contents For nonlinear multispectral computed tomography (CT), accurate and fast image reconstruction is challenging when the scanning geometries under different X-ray energy spectra are inconsistent or mismatched. Motivated by this, we propose an Accurate and Fast Image REconstruction (AFIRE) algorithm to address such problems in the case of mildly full scan. From the continuous (resp. discrete) setting, we discover that the derivative operator (gradient) of the involved nonlinear mapping at some special points, for example, at zero, can be represented as a composition (block multiplication) of a diagonal operator (matrix) composed of X-ray transforms (projection matrices) and a very small-scale matrix. Based on these insights, the AFIRE algorithm is proposed by leveraging the simplified Newton method. Under proper conditions, we establish the convergence theory of the proposed algorithm. Furthermore, numerical experiments are also carried out to verify that the proposed algorithm can accurately and effectively reconstruct the basis images in completely geometric-inconsistent dual-energy CT with noiseless and noisy projection data. Particularly, the proposed algorithm significantly outperforms some state-of-the-art methods in terms of accuracy and efficiency. Finally, the flexibility and extensibility of the proposed algorithm are also demonstrated.
format Preprint
id arxiv_https___arxiv_org_abs_2505_24793
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle AFIRE: Accurate and Fast Image Reconstruction Algorithm for Geometric-inconsistent Multispectral CT
Gao, Yu
Chen, Chong
Numerical Analysis
Medical Physics
65J15, 65R32, 65J22, 68U10
For nonlinear multispectral computed tomography (CT), accurate and fast image reconstruction is challenging when the scanning geometries under different X-ray energy spectra are inconsistent or mismatched. Motivated by this, we propose an Accurate and Fast Image REconstruction (AFIRE) algorithm to address such problems in the case of mildly full scan. From the continuous (resp. discrete) setting, we discover that the derivative operator (gradient) of the involved nonlinear mapping at some special points, for example, at zero, can be represented as a composition (block multiplication) of a diagonal operator (matrix) composed of X-ray transforms (projection matrices) and a very small-scale matrix. Based on these insights, the AFIRE algorithm is proposed by leveraging the simplified Newton method. Under proper conditions, we establish the convergence theory of the proposed algorithm. Furthermore, numerical experiments are also carried out to verify that the proposed algorithm can accurately and effectively reconstruct the basis images in completely geometric-inconsistent dual-energy CT with noiseless and noisy projection data. Particularly, the proposed algorithm significantly outperforms some state-of-the-art methods in terms of accuracy and efficiency. Finally, the flexibility and extensibility of the proposed algorithm are also demonstrated.
title AFIRE: Accurate and Fast Image Reconstruction Algorithm for Geometric-inconsistent Multispectral CT
topic Numerical Analysis
Medical Physics
65J15, 65R32, 65J22, 68U10
url https://arxiv.org/abs/2505.24793