Salvato in:
Dettagli Bibliografici
Autori principali: Ullmann, Leonie, Beißer, Florian, Behrens, Rolf, Funk, Stefan, Hilgers, Gerhard, Hupe, Oliver, Roth, Jürgen, Tröltzsch, Tom, Zutz, Hayo, Michel, Thilo
Natura: Preprint
Pubblicazione: 2025
Soggetti:
Accesso online:https://arxiv.org/abs/2506.00006
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866916948546158592
author Ullmann, Leonie
Beißer, Florian
Behrens, Rolf
Funk, Stefan
Hilgers, Gerhard
Hupe, Oliver
Roth, Jürgen
Tröltzsch, Tom
Zutz, Hayo
Michel, Thilo
author_facet Ullmann, Leonie
Beißer, Florian
Behrens, Rolf
Funk, Stefan
Hilgers, Gerhard
Hupe, Oliver
Roth, Jürgen
Tröltzsch, Tom
Zutz, Hayo
Michel, Thilo
contents In this work, the effect of the measurement position on measurements of $H_\text{p}(3)$ of a new active eye lens dosemeter prototype based on the Dosepix detector is examined. A comparison between measuring directly in front of the eye and measuring at the side of the head of an Alderson phantom showed no significant influence on the resulting $H_\text{p}(3)$ for different radiation qualities and angles. In addition, to account for the absorption effect of radiation safety glasses, pieces of lead glass were attached to the front and side of the dosemeter. Corresponding effects and consequences for radiation protection measurements have been investigated by using a human like Alderson head phantom as well as thermoluminescent dosemeters (TLDs) and the active eye lens dosemeter prototype. For specific angles, the radiation bypassed the radiation safety glasses and lead glass pieces, leading to an increase in the measured $H_\text{p}(3)$. Compared to TLDs behind radiation safety glasses, measurements with the lead glass shielded prototype resulted in lower values for $H_\text{p}(3)$. Furthermore, the results did not reproduce previous findings where larger dose values were found for Dosepix behind lead glass pieces than for the TLDs behind radiation safety glasses. A possible reason might be that the dimensions of the lead glass pieces are not representative of the radiation safety glasses in front of the eye but, ultimately, it is not yet clear what the main reason for the deviation is. Therefore, it is advisable to test the same methodology in future investigations with other eyewear models and lead glass pieces to investigate whether similar behaviors occur.
format Preprint
id arxiv_https___arxiv_org_abs_2506_00006
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Active Eye Lens Dosimetry With Dosepix: Influence of Measurement Position and Lead Glass Shielding
Ullmann, Leonie
Beißer, Florian
Behrens, Rolf
Funk, Stefan
Hilgers, Gerhard
Hupe, Oliver
Roth, Jürgen
Tröltzsch, Tom
Zutz, Hayo
Michel, Thilo
Medical Physics
In this work, the effect of the measurement position on measurements of $H_\text{p}(3)$ of a new active eye lens dosemeter prototype based on the Dosepix detector is examined. A comparison between measuring directly in front of the eye and measuring at the side of the head of an Alderson phantom showed no significant influence on the resulting $H_\text{p}(3)$ for different radiation qualities and angles. In addition, to account for the absorption effect of radiation safety glasses, pieces of lead glass were attached to the front and side of the dosemeter. Corresponding effects and consequences for radiation protection measurements have been investigated by using a human like Alderson head phantom as well as thermoluminescent dosemeters (TLDs) and the active eye lens dosemeter prototype. For specific angles, the radiation bypassed the radiation safety glasses and lead glass pieces, leading to an increase in the measured $H_\text{p}(3)$. Compared to TLDs behind radiation safety glasses, measurements with the lead glass shielded prototype resulted in lower values for $H_\text{p}(3)$. Furthermore, the results did not reproduce previous findings where larger dose values were found for Dosepix behind lead glass pieces than for the TLDs behind radiation safety glasses. A possible reason might be that the dimensions of the lead glass pieces are not representative of the radiation safety glasses in front of the eye but, ultimately, it is not yet clear what the main reason for the deviation is. Therefore, it is advisable to test the same methodology in future investigations with other eyewear models and lead glass pieces to investigate whether similar behaviors occur.
title Active Eye Lens Dosimetry With Dosepix: Influence of Measurement Position and Lead Glass Shielding