X-ray mirror figure correction using differential deposition

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Morawe, Ch., Labouré, S., Perrin, F., Vivo, A., Barrett, R.
Format: Preprint
Veröffentlicht: 2025
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866910980252893184
author Morawe, Ch.
Labouré, S.
Perrin, F.
Vivo, A.
Barrett, R.
author_facet Morawe, Ch.
Labouré, S.
Perrin, F.
Vivo, A.
Barrett, R.
contents The surface figure of x-ray mirrors can be improved by differential deposition of thin films. To achieve the required corrections, WSi2 layers of variable thickness were deposited through beam-defining apertures of different openings. The substrates were moved in front of the particle source with specific velocity profiles that were calculated with a deconvolution algorithm. Two different DC magnetron sputter systems were used to investigate the correction process. Height errors were evaluated before and after each iteration using off-line visible light surface metrology. Four 300 mm long flat Si mirrors were used to study the impact of the initial shape errors on the performance of the correction approach. The shape errors were routinely reduced by a factor of 20-30 down to levels below 0.5 nm RMS.
format Preprint
id arxiv_https___arxiv_org_abs_2506_01409
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle X-ray mirror figure correction using differential deposition
Morawe, Ch.
Labouré, S.
Perrin, F.
Vivo, A.
Barrett, R.
Optics
Applied Physics
The surface figure of x-ray mirrors can be improved by differential deposition of thin films. To achieve the required corrections, WSi2 layers of variable thickness were deposited through beam-defining apertures of different openings. The substrates were moved in front of the particle source with specific velocity profiles that were calculated with a deconvolution algorithm. Two different DC magnetron sputter systems were used to investigate the correction process. Height errors were evaluated before and after each iteration using off-line visible light surface metrology. Four 300 mm long flat Si mirrors were used to study the impact of the initial shape errors on the performance of the correction approach. The shape errors were routinely reduced by a factor of 20-30 down to levels below 0.5 nm RMS.
title X-ray mirror figure correction using differential deposition
topic Optics
Applied Physics
url https://arxiv.org/abs/2506.01409