Verification of the Timing System for the X-ray Imaging and Spectroscopy Mission in the GPS Unsynchronized Mode

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Shidatsu, Megumi, Terada, Yukikatsu, Kominato, Takashi, Kato, So, Sato, Ryohei, Sakama, Minami, Shioiri, Takumi, Motogami, Yugo, Niida, Yuuki, Kang, Chulsoo, Takagi, Toshihiro, Nakamoto, Taichi, Natsukari, Chikara, Tashiro, Makoto S., Toda, Kenichi, Maejima, Hironori, Watanabe, Shin, Iizuka, Ryo, Sato, Rie, Baluta, Chris, Hayashi, Katsuhiro, Yoshida, Tessei, Ogawa, Shoji, Kanemaru, Yoshiaki, Fukushima, Kotaro, Hoshino, Akio, Takahashi, Hiromitsu, Nobukawa, Masayoshi, Mizuno, Tsunefumi, Nakazawa, Kazuhiro, Uno, Shinichiro, Ebisawa, Ken, Eguchi, Satoshi, Katsuda, Satoru, Kubota, Aya, Ota, Naomi, Tanimoto, Atsushi, Terashima, Yuichi, Tsuboi, Yohko, Uchida, Yuusuke, Uchiyama, Hideki, Yamauchi, Shigeo, Yoneyama, Tomokage, Yamada, Satoshi, Uchida, Nagomi, Holland, Matt, Loewenstein, Michael, Yaqoob, Tahir, Miller, Eric D., Hill, Robert S., Perez-Solis, Efrain C., Waddy, Morgan D., Mekosh, Mark, Fox, Joseph B., Brewer, Isabella S., Aldoretta, Emily, Mukai, Koji, Hamaguchi, Kenji, Mernier, Francois, Ogorzalek, Anna, Pottschmidt, Katja, Yukita, Mihoko
Format: Preprint
Published: 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866916775693647872
author Shidatsu, Megumi
Terada, Yukikatsu
Kominato, Takashi
Kato, So
Sato, Ryohei
Sakama, Minami
Shioiri, Takumi
Motogami, Yugo
Niida, Yuuki
Kang, Chulsoo
Takagi, Toshihiro
Nakamoto, Taichi
Natsukari, Chikara
Tashiro, Makoto S.
Toda, Kenichi
Maejima, Hironori
Watanabe, Shin
Iizuka, Ryo
Sato, Rie
Baluta, Chris
Hayashi, Katsuhiro
Yoshida, Tessei
Ogawa, Shoji
Kanemaru, Yoshiaki
Fukushima, Kotaro
Hoshino, Akio
Takahashi, Hiromitsu
Nobukawa, Masayoshi
Mizuno, Tsunefumi
Nakazawa, Kazuhiro
Uno, Shinichiro
Ebisawa, Ken
Eguchi, Satoshi
Katsuda, Satoru
Kubota, Aya
Ota, Naomi
Tanimoto, Atsushi
Terashima, Yuichi
Tsuboi, Yohko
Uchida, Yuusuke
Uchiyama, Hideki
Yamauchi, Shigeo
Yoneyama, Tomokage
Yamada, Satoshi
Uchida, Nagomi
Holland, Matt
Loewenstein, Michael
Yaqoob, Tahir
Miller, Eric D.
Hill, Robert S.
Perez-Solis, Efrain C.
Waddy, Morgan D.
Mekosh, Mark
Fox, Joseph B.
Brewer, Isabella S.
Aldoretta, Emily
Mukai, Koji
Hamaguchi, Kenji
Mernier, Francois
Ogorzalek, Anna
Pottschmidt, Katja
Yukita, Mihoko
author_facet Shidatsu, Megumi
Terada, Yukikatsu
Kominato, Takashi
Kato, So
Sato, Ryohei
Sakama, Minami
Shioiri, Takumi
Motogami, Yugo
Niida, Yuuki
Kang, Chulsoo
Takagi, Toshihiro
Nakamoto, Taichi
Natsukari, Chikara
Tashiro, Makoto S.
Toda, Kenichi
Maejima, Hironori
Watanabe, Shin
Iizuka, Ryo
Sato, Rie
Baluta, Chris
Hayashi, Katsuhiro
Yoshida, Tessei
Ogawa, Shoji
Kanemaru, Yoshiaki
Fukushima, Kotaro
Hoshino, Akio
Takahashi, Hiromitsu
Nobukawa, Masayoshi
Mizuno, Tsunefumi
Nakazawa, Kazuhiro
Uno, Shinichiro
Ebisawa, Ken
Eguchi, Satoshi
Katsuda, Satoru
Kubota, Aya
Ota, Naomi
Tanimoto, Atsushi
Terashima, Yuichi
Tsuboi, Yohko
Uchida, Yuusuke
Uchiyama, Hideki
Yamauchi, Shigeo
Yoneyama, Tomokage
Yamada, Satoshi
Uchida, Nagomi
Holland, Matt
Loewenstein, Michael
Yaqoob, Tahir
Miller, Eric D.
Hill, Robert S.
Perez-Solis, Efrain C.
Waddy, Morgan D.
Mekosh, Mark
Fox, Joseph B.
Brewer, Isabella S.
Aldoretta, Emily
Mukai, Koji
Hamaguchi, Kenji
Mernier, Francois
Ogorzalek, Anna
Pottschmidt, Katja
Yukita, Mihoko
contents We report the results from the ground and on-orbit verifications of the XRISM timing system when the satellite clock is not synchronized to the GPS time. In this case, the time is determined by a free-run quartz oscillator of the clock, whose frequency changes depending on its temperature. In the thermal vacuum test performed in 2022, we obtained the GPS unsynchronized mode data and the temperature-versus-clock frequency trend. Comparing the time values calculated from the data and the true GPS times when the data were obtained, we confirmed that the requirement (within a 350 $μ$s error in the absolute time, accounting for both the spacecraft bus system and the ground system) was satisfied in the temperature conditions of the thermal vacuum test. We also simulated the variation of the timing accuracy in the on-orbit temperature conditions using the Hitomi on-orbit temperature data and found that the error remained within the requirement over $\sim 3 \times 10^{5}$ s. The on-orbit tests were conducted in 2023 September and October as part of the bus system checkout. The temperature versus clock frequency trend remained unchanged from that obtained in the thermal vacuum test and the observed time drift was consistent with that expected from the trend.
format Preprint
id arxiv_https___arxiv_org_abs_2506_02967
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Verification of the Timing System for the X-ray Imaging and Spectroscopy Mission in the GPS Unsynchronized Mode
Shidatsu, Megumi
Terada, Yukikatsu
Kominato, Takashi
Kato, So
Sato, Ryohei
Sakama, Minami
Shioiri, Takumi
Motogami, Yugo
Niida, Yuuki
Kang, Chulsoo
Takagi, Toshihiro
Nakamoto, Taichi
Natsukari, Chikara
Tashiro, Makoto S.
Toda, Kenichi
Maejima, Hironori
Watanabe, Shin
Iizuka, Ryo
Sato, Rie
Baluta, Chris
Hayashi, Katsuhiro
Yoshida, Tessei
Ogawa, Shoji
Kanemaru, Yoshiaki
Fukushima, Kotaro
Hoshino, Akio
Takahashi, Hiromitsu
Nobukawa, Masayoshi
Mizuno, Tsunefumi
Nakazawa, Kazuhiro
Uno, Shinichiro
Ebisawa, Ken
Eguchi, Satoshi
Katsuda, Satoru
Kubota, Aya
Ota, Naomi
Tanimoto, Atsushi
Terashima, Yuichi
Tsuboi, Yohko
Uchida, Yuusuke
Uchiyama, Hideki
Yamauchi, Shigeo
Yoneyama, Tomokage
Yamada, Satoshi
Uchida, Nagomi
Holland, Matt
Loewenstein, Michael
Yaqoob, Tahir
Miller, Eric D.
Hill, Robert S.
Perez-Solis, Efrain C.
Waddy, Morgan D.
Mekosh, Mark
Fox, Joseph B.
Brewer, Isabella S.
Aldoretta, Emily
Mukai, Koji
Hamaguchi, Kenji
Mernier, Francois
Ogorzalek, Anna
Pottschmidt, Katja
Yukita, Mihoko
Instrumentation and Methods for Astrophysics
We report the results from the ground and on-orbit verifications of the XRISM timing system when the satellite clock is not synchronized to the GPS time. In this case, the time is determined by a free-run quartz oscillator of the clock, whose frequency changes depending on its temperature. In the thermal vacuum test performed in 2022, we obtained the GPS unsynchronized mode data and the temperature-versus-clock frequency trend. Comparing the time values calculated from the data and the true GPS times when the data were obtained, we confirmed that the requirement (within a 350 $μ$s error in the absolute time, accounting for both the spacecraft bus system and the ground system) was satisfied in the temperature conditions of the thermal vacuum test. We also simulated the variation of the timing accuracy in the on-orbit temperature conditions using the Hitomi on-orbit temperature data and found that the error remained within the requirement over $\sim 3 \times 10^{5}$ s. The on-orbit tests were conducted in 2023 September and October as part of the bus system checkout. The temperature versus clock frequency trend remained unchanged from that obtained in the thermal vacuum test and the observed time drift was consistent with that expected from the trend.
title Verification of the Timing System for the X-ray Imaging and Spectroscopy Mission in the GPS Unsynchronized Mode
topic Instrumentation and Methods for Astrophysics
url https://arxiv.org/abs/2506.02967