A high-sensitivity frequency counter for free-induction-decay signals

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Gong, Tong, Shu, Ming-Rui, He, Jiang, Liu, Kai, Li, Yi-Ren, Hao, Xin-Jun, Sheng, Dong, Wang, Yu-Ming, Feng, Yu-Kun
Natura: Preprint
Pubblicazione: 2025
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866915327722389504
author Gong, Tong
Shu, Ming-Rui
He, Jiang
Liu, Kai
Li, Yi-Ren
Hao, Xin-Jun
Sheng, Dong
Wang, Yu-Ming
Feng, Yu-Kun
author_facet Gong, Tong
Shu, Ming-Rui
He, Jiang
Liu, Kai
Li, Yi-Ren
Hao, Xin-Jun
Sheng, Dong
Wang, Yu-Ming
Feng, Yu-Kun
contents Real-time frequency readout of time-dependent pulsed signals with a high sensitivity are key elements in many applications using atomic devices, such as FID atomic magnetometers. In this paper, we propose a frequency measurement algorithm based on the Hilbert transform and implement such a scheme in a FPGA-based frequency counter. By testing pulsed exponential-decay oscillation signals in the frequency range of 10 to 500 kHz, this frequency counter shows a frequency sensitivity better than 0.1 mHz/Hz^(1/2) at 10 Hz, with an output rate of 200 Hz. When the output rate is increased to 1000 Hz, the sensitivity remains better than 0.4 mHz/Hz^(1/2) at 10 Hz. The performance on frequency sensitivity is comparable with results obtained by off-line nonlinear fitting processes. In addition, this frequency counter does not require the pre-knowledge of the analytic expression of the input signals. The realization of such a device paves the way for practical applications of highly-sensitive FID atomic magnetometers.
format Preprint
id arxiv_https___arxiv_org_abs_2506_04780
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle A high-sensitivity frequency counter for free-induction-decay signals
Gong, Tong
Shu, Ming-Rui
He, Jiang
Liu, Kai
Li, Yi-Ren
Hao, Xin-Jun
Sheng, Dong
Wang, Yu-Ming
Feng, Yu-Kun
Instrumentation and Detectors
Atomic Physics
Real-time frequency readout of time-dependent pulsed signals with a high sensitivity are key elements in many applications using atomic devices, such as FID atomic magnetometers. In this paper, we propose a frequency measurement algorithm based on the Hilbert transform and implement such a scheme in a FPGA-based frequency counter. By testing pulsed exponential-decay oscillation signals in the frequency range of 10 to 500 kHz, this frequency counter shows a frequency sensitivity better than 0.1 mHz/Hz^(1/2) at 10 Hz, with an output rate of 200 Hz. When the output rate is increased to 1000 Hz, the sensitivity remains better than 0.4 mHz/Hz^(1/2) at 10 Hz. The performance on frequency sensitivity is comparable with results obtained by off-line nonlinear fitting processes. In addition, this frequency counter does not require the pre-knowledge of the analytic expression of the input signals. The realization of such a device paves the way for practical applications of highly-sensitive FID atomic magnetometers.
title A high-sensitivity frequency counter for free-induction-decay signals
topic Instrumentation and Detectors
Atomic Physics
url https://arxiv.org/abs/2506.04780