Direct optimization of the probability of lesion origin in proton treatment planning for low-grade glioma patients

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Ortkamp, Tim, Sallem, Habiba, Harrabi, Semi, Frank, Martin, Jäkel, Oliver, Bauer, Julia, Wahl, Niklas
Format: Preprint
Published: 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866917408951762944
author Ortkamp, Tim
Sallem, Habiba
Harrabi, Semi
Frank, Martin
Jäkel, Oliver
Bauer, Julia
Wahl, Niklas
author_facet Ortkamp, Tim
Sallem, Habiba
Harrabi, Semi
Frank, Martin
Jäkel, Oliver
Bauer, Julia
Wahl, Niklas
contents In proton therapy of low-grade glioma (LGG) patients, contrast-enhancing brain lesions (CEBLs) on magnetic resonance imaging are considered predictive of late radiation-induced lesions. From the observation that CEBLs tend to concentrate in regions of increased dose-averaged linear energy transfer (LET$_{\text{d}}$) and proximal to the ventricular system, the probability of lesion origin (POLO) model has been established as a multivariate logistic regression model for the voxel-wise probability prediction of the CEBL origin. To date, leveraging the predictive power of the POLO model for treatment planning relies on hand tuning the dose and LET$_{\text{d}}$ distribution to minimize the resulting probability predictions. In this paper, we therefore propose automated POLO model-based treatment planning by directly integrating POLO calculation and optimization into plan optimization for LGG patients. We introduce an extension of the original POLO model including a volumetric correction factor, and a model-based optimization scheme featuring a linear reformulation of the model together with feasible optimization functions based on the predicted POLO values. The developed framework is implemented in the open-source treatment planning toolkit matRad. Our framework can generate clinically acceptable treatment plans while automatically taking into account outcome predictions from the POLO model. It also supports the definition of customized POLO model-based objective and constraint functions. Optimization results from a sample LGG patient show that the POLO model-based outcome predictions can be minimized under expectable shifts in dose, LET$_{\text{d}}$, and POLO distributions, while sustaining target coverage ($Δ_{\text{PTV}} \text{D95}_{RBE,fx}\approx{0.00}$, $Δ_{\text{GTV}} \text{D95}_{RBE,fx}\approx{0.03}$), even when NTCP is strongly down-regulated.
format Preprint
id arxiv_https___arxiv_org_abs_2506_13539
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Direct optimization of the probability of lesion origin in proton treatment planning for low-grade glioma patients
Ortkamp, Tim
Sallem, Habiba
Harrabi, Semi
Frank, Martin
Jäkel, Oliver
Bauer, Julia
Wahl, Niklas
Medical Physics
In proton therapy of low-grade glioma (LGG) patients, contrast-enhancing brain lesions (CEBLs) on magnetic resonance imaging are considered predictive of late radiation-induced lesions. From the observation that CEBLs tend to concentrate in regions of increased dose-averaged linear energy transfer (LET$_{\text{d}}$) and proximal to the ventricular system, the probability of lesion origin (POLO) model has been established as a multivariate logistic regression model for the voxel-wise probability prediction of the CEBL origin. To date, leveraging the predictive power of the POLO model for treatment planning relies on hand tuning the dose and LET$_{\text{d}}$ distribution to minimize the resulting probability predictions. In this paper, we therefore propose automated POLO model-based treatment planning by directly integrating POLO calculation and optimization into plan optimization for LGG patients. We introduce an extension of the original POLO model including a volumetric correction factor, and a model-based optimization scheme featuring a linear reformulation of the model together with feasible optimization functions based on the predicted POLO values. The developed framework is implemented in the open-source treatment planning toolkit matRad. Our framework can generate clinically acceptable treatment plans while automatically taking into account outcome predictions from the POLO model. It also supports the definition of customized POLO model-based objective and constraint functions. Optimization results from a sample LGG patient show that the POLO model-based outcome predictions can be minimized under expectable shifts in dose, LET$_{\text{d}}$, and POLO distributions, while sustaining target coverage ($Δ_{\text{PTV}} \text{D95}_{RBE,fx}\approx{0.00}$, $Δ_{\text{GTV}} \text{D95}_{RBE,fx}\approx{0.03}$), even when NTCP is strongly down-regulated.
title Direct optimization of the probability of lesion origin in proton treatment planning for low-grade glioma patients
topic Medical Physics
url https://arxiv.org/abs/2506.13539