Impact of embedded $^{163}$Ho on the performance of the transition-edge sensor microcalorimeters of the HOLMES experiment

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Bennett, Douglas, Borghesi, Matteo, Campana, Pietro, Carobene, Rodolfo, Ceruti, Giancarlo, De Gerone, Matteo, Faverzani, Marco, Barusso, Lorenzo Ferrari, Ferri, Elena, Fowler, Joseph, Gamba, Sara, Gatti, Flavio, Giachero, Andrea, Gobbo, Marco, Labranca, Danilo, Moretti, Roberto, Nucciotti, Angelo, Origo, Luca, Ragazzi, Stefano, Schmidt, Dan, Swetz, Daniel, Ullom, Joel
Formato: Preprint
Publicado: 2025
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866912621964296192
author Bennett, Douglas
Borghesi, Matteo
Campana, Pietro
Carobene, Rodolfo
Ceruti, Giancarlo
De Gerone, Matteo
Faverzani, Marco
Barusso, Lorenzo Ferrari
Ferri, Elena
Fowler, Joseph
Gamba, Sara
Gatti, Flavio
Giachero, Andrea
Gobbo, Marco
Labranca, Danilo
Moretti, Roberto
Nucciotti, Angelo
Origo, Luca
Ragazzi, Stefano
Schmidt, Dan
Swetz, Daniel
Ullom, Joel
author_facet Bennett, Douglas
Borghesi, Matteo
Campana, Pietro
Carobene, Rodolfo
Ceruti, Giancarlo
De Gerone, Matteo
Faverzani, Marco
Barusso, Lorenzo Ferrari
Ferri, Elena
Fowler, Joseph
Gamba, Sara
Gatti, Flavio
Giachero, Andrea
Gobbo, Marco
Labranca, Danilo
Moretti, Roberto
Nucciotti, Angelo
Origo, Luca
Ragazzi, Stefano
Schmidt, Dan
Swetz, Daniel
Ullom, Joel
contents We present a detailed investigation of the performance of transition-edge sensor (TES) microcalorimeters with $^{163}$Ho atoms embedded by ion implantation, as part of the HOLMES experiment aimed at neutrino mass determination. The inclusion of $^{163}$Ho atoms introduces an excess heat capacity due to a pronounced Schottky anomaly, which can affect the detector's energy resolution, signal height, and response time. We fabricated TES arrays with varying levels of $^{163}$Ho activity and characterized their performance in terms of energy resolution, decay time constants, and heat capacity. The intrinsic energy resolution was found to degrade with increasing $^{163}$Ho activity, consistent with the expected scaling of heat capacity. From the analysis, we determined the specific heat capacity of $^{163}$Ho to be $(2.9 \pm 0.4 \mathrm{(stat)} \pm 0.7 \mathrm{(sys)})$ J/K/mol at $(94 \pm 1)$\,mK, close to the literature values for metallic holmium. No additional long decay time constants correlated with $^{163}$Ho activity were observed, indicating that the excess heat capacity does not introduce weakly coupled thermodynamic systems. These results suggest that our present TES microcalorimeters can tolerate $^{163}$Ho activities up to approximately 5 Bq without significant performance degradation. For higher activities, reducing the TES transition temperature is necessary to maintain energy resolution. These findings provide critical insights for optimizing TES microcalorimeters for future neutrino mass experiments and other applications requiring embedded radioactive sources. The study also highlights the robustness of TES technology in handling implanted radionuclides while maintaining high-resolution performance.
format Preprint
id arxiv_https___arxiv_org_abs_2506_13665
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Impact of embedded $^{163}$Ho on the performance of the transition-edge sensor microcalorimeters of the HOLMES experiment
Bennett, Douglas
Borghesi, Matteo
Campana, Pietro
Carobene, Rodolfo
Ceruti, Giancarlo
De Gerone, Matteo
Faverzani, Marco
Barusso, Lorenzo Ferrari
Ferri, Elena
Fowler, Joseph
Gamba, Sara
Gatti, Flavio
Giachero, Andrea
Gobbo, Marco
Labranca, Danilo
Moretti, Roberto
Nucciotti, Angelo
Origo, Luca
Ragazzi, Stefano
Schmidt, Dan
Swetz, Daniel
Ullom, Joel
Instrumentation and Detectors
Nuclear Experiment
We present a detailed investigation of the performance of transition-edge sensor (TES) microcalorimeters with $^{163}$Ho atoms embedded by ion implantation, as part of the HOLMES experiment aimed at neutrino mass determination. The inclusion of $^{163}$Ho atoms introduces an excess heat capacity due to a pronounced Schottky anomaly, which can affect the detector's energy resolution, signal height, and response time. We fabricated TES arrays with varying levels of $^{163}$Ho activity and characterized their performance in terms of energy resolution, decay time constants, and heat capacity. The intrinsic energy resolution was found to degrade with increasing $^{163}$Ho activity, consistent with the expected scaling of heat capacity. From the analysis, we determined the specific heat capacity of $^{163}$Ho to be $(2.9 \pm 0.4 \mathrm{(stat)} \pm 0.7 \mathrm{(sys)})$ J/K/mol at $(94 \pm 1)$\,mK, close to the literature values for metallic holmium. No additional long decay time constants correlated with $^{163}$Ho activity were observed, indicating that the excess heat capacity does not introduce weakly coupled thermodynamic systems. These results suggest that our present TES microcalorimeters can tolerate $^{163}$Ho activities up to approximately 5 Bq without significant performance degradation. For higher activities, reducing the TES transition temperature is necessary to maintain energy resolution. These findings provide critical insights for optimizing TES microcalorimeters for future neutrino mass experiments and other applications requiring embedded radioactive sources. The study also highlights the robustness of TES technology in handling implanted radionuclides while maintaining high-resolution performance.
title Impact of embedded $^{163}$Ho on the performance of the transition-edge sensor microcalorimeters of the HOLMES experiment
topic Instrumentation and Detectors
Nuclear Experiment
url https://arxiv.org/abs/2506.13665