Development of non amplified Depleted MAPS sensors towards 50 ps timing resolution on charged particles

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Casanova, Raimon, Degerli, Yavuz, Gan, Yujing, Grinstein, Sebastian, Guilloux, Fabrice, Hemperek, Tomasz, Huang, G., Meyer, Jean-Pierre, Schwemling, Philippe
Natura: Preprint
Pubblicazione: 2025
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866918060412108800
author Casanova, Raimon
Degerli, Yavuz
Gan, Yujing
Grinstein, Sebastian
Guilloux, Fabrice
Hemperek, Tomasz
Huang, G.
Meyer, Jean-Pierre
Schwemling, Philippe
author_facet Casanova, Raimon
Degerli, Yavuz
Gan, Yujing
Grinstein, Sebastian
Guilloux, Fabrice
Hemperek, Tomasz
Huang, G.
Meyer, Jean-Pierre
Schwemling, Philippe
contents The MiniCactus sensors are demonstrator sensors designed in LFoundry LF15A 150 nm technology, intended to study the performance of non amplified High Voltage High Resistivity CMOS sensors for measurement of time of arrival of charged particles. This paper presents the context, design features and some of the first test-beam results obtained with the latest MiniCactus sensor version, MiniCactus V2. With a 175 micron thick sensor biased at -350 V, we have obtained a 60 ps time resolution on Minimum Ionizing Particles detected with a 500 micron by 500 micron pixel.
format Preprint
id arxiv_https___arxiv_org_abs_2506_13999
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Development of non amplified Depleted MAPS sensors towards 50 ps timing resolution on charged particles
Casanova, Raimon
Degerli, Yavuz
Gan, Yujing
Grinstein, Sebastian
Guilloux, Fabrice
Hemperek, Tomasz
Huang, G.
Meyer, Jean-Pierre
Schwemling, Philippe
Instrumentation and Detectors
High Energy Physics - Experiment
The MiniCactus sensors are demonstrator sensors designed in LFoundry LF15A 150 nm technology, intended to study the performance of non amplified High Voltage High Resistivity CMOS sensors for measurement of time of arrival of charged particles. This paper presents the context, design features and some of the first test-beam results obtained with the latest MiniCactus sensor version, MiniCactus V2. With a 175 micron thick sensor biased at -350 V, we have obtained a 60 ps time resolution on Minimum Ionizing Particles detected with a 500 micron by 500 micron pixel.
title Development of non amplified Depleted MAPS sensors towards 50 ps timing resolution on charged particles
topic Instrumentation and Detectors
High Energy Physics - Experiment
url https://arxiv.org/abs/2506.13999