Determining the Validity of Tokamak Perturbed Equilibrium Modeling Using Nonlinear Equilibria

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Halpern, J., Logan, N. C., Paul, E., Paz-Soldan, C.
Format: Preprint
Published: 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866915514162348032
author Halpern, J.
Logan, N. C.
Paul, E.
Paz-Soldan, C.
author_facet Halpern, J.
Logan, N. C.
Paul, E.
Paz-Soldan, C.
contents The prediction of perturbed equilibrium models for tokamaks with small 3D fields is strongly dependent on which reference frame for axisymmetry is assumed - for example, the toroidal field (TF) coil vs the poloidal field (PF) coil centroid. We use fully 3D equilibria generated by VMEC to determine the correct reference frame in these models when subject to n=1 coil asymmetries. We analyze a case for SPARC and find that the appropriate frame can be well approximated by the centroid of the TF coil set. We also consider the case of NSTX-U and find that the frame can be approximated by the radial location of the TF coil inboard legs at the midplane. We determine the correct frame by analyzing the shifted magnetic axis in the nonlinear equilibria. We also analyze the magnetic field line displacement to identify where the linearized MHD theory begins to break down, and compare that to typical coil tolerances in existing tokamaks. We find that linear theory is valid for existing tolerances, validating the use of perturbative codes to set these tolerances, but with a sufficiently small margin to be of note for future devices with relative tolerances larger than approximately $1\%$ of the minor radius. This study enables engineers to confidently use 3D perturbative models for determining assembly tolerances by providing insight into the correct applications of the theory.
format Preprint
id arxiv_https___arxiv_org_abs_2506_14938
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Determining the Validity of Tokamak Perturbed Equilibrium Modeling Using Nonlinear Equilibria
Halpern, J.
Logan, N. C.
Paul, E.
Paz-Soldan, C.
Plasma Physics
The prediction of perturbed equilibrium models for tokamaks with small 3D fields is strongly dependent on which reference frame for axisymmetry is assumed - for example, the toroidal field (TF) coil vs the poloidal field (PF) coil centroid. We use fully 3D equilibria generated by VMEC to determine the correct reference frame in these models when subject to n=1 coil asymmetries. We analyze a case for SPARC and find that the appropriate frame can be well approximated by the centroid of the TF coil set. We also consider the case of NSTX-U and find that the frame can be approximated by the radial location of the TF coil inboard legs at the midplane. We determine the correct frame by analyzing the shifted magnetic axis in the nonlinear equilibria. We also analyze the magnetic field line displacement to identify where the linearized MHD theory begins to break down, and compare that to typical coil tolerances in existing tokamaks. We find that linear theory is valid for existing tolerances, validating the use of perturbative codes to set these tolerances, but with a sufficiently small margin to be of note for future devices with relative tolerances larger than approximately $1\%$ of the minor radius. This study enables engineers to confidently use 3D perturbative models for determining assembly tolerances by providing insight into the correct applications of the theory.
title Determining the Validity of Tokamak Perturbed Equilibrium Modeling Using Nonlinear Equilibria
topic Plasma Physics
url https://arxiv.org/abs/2506.14938