Revisiting XDoppler estimator for high spatiotemporal resolution volumetric axial velocity measurement using row-column arrays

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Leroy, Henri, Bertolo, Adrien, Goudot, Guillaume, Tanter, Mickael, Deffieux, Thomas, Pernot, Mathieu
Format: Preprint
Published: 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866915968877330432
author Leroy, Henri
Bertolo, Adrien
Goudot, Guillaume
Tanter, Mickael
Deffieux, Thomas
Pernot, Mathieu
author_facet Leroy, Henri
Bertolo, Adrien
Goudot, Guillaume
Tanter, Mickael
Deffieux, Thomas
Pernot, Mathieu
contents Accurate volumetric velocity estimation is crucial in ultrasound imaging for both diagnostic and therapeutic applications. Traditional ultrasound systems, though effective for two-dimensional imaging, face major limitations in 3D imaging due to hardware and computational demands. Row-column addressed (RCA) ultrasound probes offer a promising alternative by reducing hardware complexity, thereby reducing the gap between research prototypes and clinical systems. However, this typically comes at the expense of stronger sidelobes compared with fully populated matrix arrays, leading to reduced image contrast. Several approaches have been proposed to improve the contrast of power Doppler imaging, yet the accuracy and performance of velocity Doppler estimation have received comparatively little attention. In this study, we present a method that exploits the phase information from RCA row and column signals to derive a novel velocity estimator based on cross-correlation of orthogonal apertures. This extends the XDoppler scheme, initially developed for power Doppler imaging, to velocity estimation. The XDoppler estimator is shown to provide accurate measurements of axial velocities and to outperform the traditional phase-shift autocorrelator, while offering a theoretical Nyquist velocity twice as high. In vitro experiments further demonstrate enhanced sensitivity to slow flows and reduced bias in flow rate estimation. In vivo data from a carotid artery confirm the reduced sensitivity to aliasing and reveal the ability to track dynamic blood flow velocity changes associated with arterial pulsatility. These findings suggest that the XDoppler velocity estimator could improve volumetric velocity imaging in clinical contexts.
format Preprint
id arxiv_https___arxiv_org_abs_2506_15469
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Revisiting XDoppler estimator for high spatiotemporal resolution volumetric axial velocity measurement using row-column arrays
Leroy, Henri
Bertolo, Adrien
Goudot, Guillaume
Tanter, Mickael
Deffieux, Thomas
Pernot, Mathieu
Medical Physics
Applied Physics
Accurate volumetric velocity estimation is crucial in ultrasound imaging for both diagnostic and therapeutic applications. Traditional ultrasound systems, though effective for two-dimensional imaging, face major limitations in 3D imaging due to hardware and computational demands. Row-column addressed (RCA) ultrasound probes offer a promising alternative by reducing hardware complexity, thereby reducing the gap between research prototypes and clinical systems. However, this typically comes at the expense of stronger sidelobes compared with fully populated matrix arrays, leading to reduced image contrast. Several approaches have been proposed to improve the contrast of power Doppler imaging, yet the accuracy and performance of velocity Doppler estimation have received comparatively little attention. In this study, we present a method that exploits the phase information from RCA row and column signals to derive a novel velocity estimator based on cross-correlation of orthogonal apertures. This extends the XDoppler scheme, initially developed for power Doppler imaging, to velocity estimation. The XDoppler estimator is shown to provide accurate measurements of axial velocities and to outperform the traditional phase-shift autocorrelator, while offering a theoretical Nyquist velocity twice as high. In vitro experiments further demonstrate enhanced sensitivity to slow flows and reduced bias in flow rate estimation. In vivo data from a carotid artery confirm the reduced sensitivity to aliasing and reveal the ability to track dynamic blood flow velocity changes associated with arterial pulsatility. These findings suggest that the XDoppler velocity estimator could improve volumetric velocity imaging in clinical contexts.
title Revisiting XDoppler estimator for high spatiotemporal resolution volumetric axial velocity measurement using row-column arrays
topic Medical Physics
Applied Physics
url https://arxiv.org/abs/2506.15469