[Beat-to-beat AV nodal assessment] ECG-based beat-to-beat assessment of AV node conduction properties during AF

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Karlsson, Mattias, Plappert, Felix, Platonov, Pyotr G, Östenson, Sten, Wallman, Mikael, Sandberg, Frida
Natura: Preprint
Pubblicazione: 2025
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866908419162636288
author Karlsson, Mattias
Plappert, Felix
Platonov, Pyotr G
Östenson, Sten
Wallman, Mikael
Sandberg, Frida
author_facet Karlsson, Mattias
Plappert, Felix
Platonov, Pyotr G
Östenson, Sten
Wallman, Mikael
Sandberg, Frida
contents The refractory period and conduction delay of the atrioventricular (AV) node play a crucial role in regulating the heart rate during atrial fibrillation (AF). Beat-to-beat variations in these properties are known to be induced by the autonomic nervous system (ANS) but have previously not been assessable during AF. Assessing these could provide novel information for improved diagnosis, prognosis, and treatment on an individual basis. To estimate AV nodal conduction properties with beat-to-beat resolution, we propose a methodology comprising a network model of the AV node, a particle filter, and a smoothing algorithm. The methodology was evaluated using simulated data and using synchronized electrogram (EGM) and ECG recordings from five patients in the intracardiac atrial fibrillation database. The methodology's ability to quantify ANS-induced changes in AV node conduction properties was evaluated by analyzing ECG data from 21 patients in AF undergoing a tilt test protocol. The estimated refractory period and conduction delay matched the simulated ground truth based on ECG recordings with a mean absolute error ($\pm$ std) of 169$\pm$14 ms for the refractory period in the fast pathway; 131$\pm$13 ms for the conduction delay in the fast pathway; 67$\pm$10 ms for the refractory period in the slow pathway; and 178$\pm$28 ms for the conduction delay in the slow pathway. These errors decreased when using simulated ground truth based on EGM recordings. Moreover, a decrease in conduction delay and refractory period in response to head-up tilt was seen during the tilt test protocol, as expected under sympathetic activation. These results suggest that beat-to-beat estimation of AV nodal conduction properties during AF from ECG is feasible, with different levels of uncertainty, and that the estimated properties agree with expected AV nodal modulation.
format Preprint
id arxiv_https___arxiv_org_abs_2506_19427
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle [Beat-to-beat AV nodal assessment] ECG-based beat-to-beat assessment of AV node conduction properties during AF
Karlsson, Mattias
Plappert, Felix
Platonov, Pyotr G
Östenson, Sten
Wallman, Mikael
Sandberg, Frida
Tissues and Organs
The refractory period and conduction delay of the atrioventricular (AV) node play a crucial role in regulating the heart rate during atrial fibrillation (AF). Beat-to-beat variations in these properties are known to be induced by the autonomic nervous system (ANS) but have previously not been assessable during AF. Assessing these could provide novel information for improved diagnosis, prognosis, and treatment on an individual basis. To estimate AV nodal conduction properties with beat-to-beat resolution, we propose a methodology comprising a network model of the AV node, a particle filter, and a smoothing algorithm. The methodology was evaluated using simulated data and using synchronized electrogram (EGM) and ECG recordings from five patients in the intracardiac atrial fibrillation database. The methodology's ability to quantify ANS-induced changes in AV node conduction properties was evaluated by analyzing ECG data from 21 patients in AF undergoing a tilt test protocol. The estimated refractory period and conduction delay matched the simulated ground truth based on ECG recordings with a mean absolute error ($\pm$ std) of 169$\pm$14 ms for the refractory period in the fast pathway; 131$\pm$13 ms for the conduction delay in the fast pathway; 67$\pm$10 ms for the refractory period in the slow pathway; and 178$\pm$28 ms for the conduction delay in the slow pathway. These errors decreased when using simulated ground truth based on EGM recordings. Moreover, a decrease in conduction delay and refractory period in response to head-up tilt was seen during the tilt test protocol, as expected under sympathetic activation. These results suggest that beat-to-beat estimation of AV nodal conduction properties during AF from ECG is feasible, with different levels of uncertainty, and that the estimated properties agree with expected AV nodal modulation.
title [Beat-to-beat AV nodal assessment] ECG-based beat-to-beat assessment of AV node conduction properties during AF
topic Tissues and Organs
url https://arxiv.org/abs/2506.19427