Volumetric segmentation of muscle compartments using in vivo imaging and architectural validation in human finger flexors

Fuente: arXiv
Saved in:
Bibliographic Details
Main Author: Li, Yang
Format: Preprint
Published: 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866908429247840256
author Li, Yang
author_facet Li, Yang
contents Segmenting muscle compartments and measuring their architecture can facilitate movement function assessment, accurate musculoskeletal modeling, and synergy-based electromyogram simulation. Here, we presented a novel method for volumetric segmentation of muscle compartments using in vivo imaging, focusing on the independent compartments for finger control of flexor digitorum superficialis (FDS). Besides, we measured the architectural properties of FDS compartments and validated the segmentation. Specifically, ultrasound and magnetic resonance imaging (MRI) from 10 healthy subjects were used for segmentation and measurement, while electromyography was utilized for validation. A two-step piecewise segmentation was proposed, first annotating compartment regions in the cross-sectional ultrasound image based on compartment movement, and then performing minimum energy matching to register the ultrasound data to the three-dimensional MRI coordinate system. Additionally, the architectural properties were measured in the compartment masks from the segmentation using MRI tractography. Anatomical correctness was verified by comparing known anatomy with reconstructed fiber tracts and measured properties, while segmentation accuracy was quantified as the percentage of finger electromyogram centers falling within their corresponding compartments. Results demonstrated agreement for the fiber orientation between the tractography and cadaveric photographs. Significant differences in architectural properties (P < 0.001) were observed between compartments. The properties of FDS and its compartments were within the physiological ranges (P < 0.01). 95% (38/40) of the electromyogram centers were located within respective compartments, with 2 errors occurring in the index and little fingers. The validated segmentation method and derived architectural properties may advance biomedical applications.
format Preprint
id arxiv_https___arxiv_org_abs_2506_20206
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Volumetric segmentation of muscle compartments using in vivo imaging and architectural validation in human finger flexors
Li, Yang
Image and Video Processing
Segmenting muscle compartments and measuring their architecture can facilitate movement function assessment, accurate musculoskeletal modeling, and synergy-based electromyogram simulation. Here, we presented a novel method for volumetric segmentation of muscle compartments using in vivo imaging, focusing on the independent compartments for finger control of flexor digitorum superficialis (FDS). Besides, we measured the architectural properties of FDS compartments and validated the segmentation. Specifically, ultrasound and magnetic resonance imaging (MRI) from 10 healthy subjects were used for segmentation and measurement, while electromyography was utilized for validation. A two-step piecewise segmentation was proposed, first annotating compartment regions in the cross-sectional ultrasound image based on compartment movement, and then performing minimum energy matching to register the ultrasound data to the three-dimensional MRI coordinate system. Additionally, the architectural properties were measured in the compartment masks from the segmentation using MRI tractography. Anatomical correctness was verified by comparing known anatomy with reconstructed fiber tracts and measured properties, while segmentation accuracy was quantified as the percentage of finger electromyogram centers falling within their corresponding compartments. Results demonstrated agreement for the fiber orientation between the tractography and cadaveric photographs. Significant differences in architectural properties (P < 0.001) were observed between compartments. The properties of FDS and its compartments were within the physiological ranges (P < 0.01). 95% (38/40) of the electromyogram centers were located within respective compartments, with 2 errors occurring in the index and little fingers. The validated segmentation method and derived architectural properties may advance biomedical applications.
title Volumetric segmentation of muscle compartments using in vivo imaging and architectural validation in human finger flexors
topic Image and Video Processing
url https://arxiv.org/abs/2506.20206