Signal-to-noise and spatial resolution in in-line imaging. 2. Phase-contrast tomography

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Gureyev, T. E., Paganin, D. M., Pavlov, K. M., Maksimenko, A., Quiney, H. M.
Format: Preprint
Publié: 2025
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866909676730318848
author Gureyev, T. E.
Paganin, D. M.
Pavlov, K. M.
Maksimenko, A.
Quiney, H. M.
author_facet Gureyev, T. E.
Paganin, D. M.
Pavlov, K. M.
Maksimenko, A.
Quiney, H. M.
contents In the first part of this paper, quantitative aspects of propagation-based phase-contrast imaging (PBI) were investigated using theoretical and numerical approaches, as well as experimental two-dimensional PBI images collected with plane monochromatic X-rays at a synchrotron beamline. In this second part, signal-to-noise ratio, spatial resolution and contrast are studied in connection with the radiation dose in three-dimensional PBI images of breast tissue samples obtained using propagation-based phase-contrast computed tomography (PB-CT) with energy-integrating and photon-counting detectors. The analysis is based on the theory of PBI and PB-CT using the homogeneous Transport of Intensity equation (Paganin's method). A biomedical image quality characteristic, suitable for quantitative assessment of X-ray images of biological samples, is introduced and applied. The key factors leading to high values of the biomedical imaging quality in PBI and to relatively low values of the same quality metric in CT imaging are identified and discussed in detail. This study is aimed primarily at developing tools for quantitative assessment and optimization of medical PB-CT imaging, initially at synchrotron facilities, with the prospect of subsequent transfer of the technology to medical clinics.
format Preprint
id arxiv_https___arxiv_org_abs_2506_20277
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Signal-to-noise and spatial resolution in in-line imaging. 2. Phase-contrast tomography
Gureyev, T. E.
Paganin, D. M.
Pavlov, K. M.
Maksimenko, A.
Quiney, H. M.
Medical Physics
In the first part of this paper, quantitative aspects of propagation-based phase-contrast imaging (PBI) were investigated using theoretical and numerical approaches, as well as experimental two-dimensional PBI images collected with plane monochromatic X-rays at a synchrotron beamline. In this second part, signal-to-noise ratio, spatial resolution and contrast are studied in connection with the radiation dose in three-dimensional PBI images of breast tissue samples obtained using propagation-based phase-contrast computed tomography (PB-CT) with energy-integrating and photon-counting detectors. The analysis is based on the theory of PBI and PB-CT using the homogeneous Transport of Intensity equation (Paganin's method). A biomedical image quality characteristic, suitable for quantitative assessment of X-ray images of biological samples, is introduced and applied. The key factors leading to high values of the biomedical imaging quality in PBI and to relatively low values of the same quality metric in CT imaging are identified and discussed in detail. This study is aimed primarily at developing tools for quantitative assessment and optimization of medical PB-CT imaging, initially at synchrotron facilities, with the prospect of subsequent transfer of the technology to medical clinics.
title Signal-to-noise and spatial resolution in in-line imaging. 2. Phase-contrast tomography
topic Medical Physics
url https://arxiv.org/abs/2506.20277