Saved in:
| Main Authors: | , , , , |
|---|---|
| Format: | Preprint |
| Published: |
2025
|
| Subjects: | |
| Online Access: | https://arxiv.org/abs/2506.23173 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Table of Contents:
- In the rapidly evolving field of optical engineering, precise alignment of multi-lens imaging systems is critical yet challenging, as even minor misalignments can significantly degrade performance. Traditional alignment methods rely on specialized equipment and are time-consuming processes, highlighting the need for automated and scalable solutions. We present two complementary deep learning-based inverse-design methods for diagnosing misalignments in multi-element lens systems using only optical measurements. First, we use ray-traced spot diagrams to predict five-degree-of-freedom (5-DOF) errors in a 6-lens photographic prime, achieving a mean absolute error of 0.031mm in lateral translation and 0.011$^\circ$ in tilt. We also introduce a physics-based simulation pipeline that utilizes grayscale synthetic camera images, enabling a deep learning model to estimate 4-DOF, decenter and tilt errors in both two- and six-lens multi-lens systems. These results show the potential to reshape manufacturing and quality control in precision imaging.