Earth's field diamond vector magnetometry with isotropic magnetic flux concentrators

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Ziabari, Maziar Saleh, Mosavian, Nazanin, Fescenko, Ilja, Silani, Yaser, Richards, Bryan A., Berzins, Andris, Aiello, Maxwell D., Lidke, Keith A., Jarmola, Andrey, Smits, Janis, Acosta, Victor M.
Format: Preprint
Published: 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866908428758155264
author Ziabari, Maziar Saleh
Mosavian, Nazanin
Fescenko, Ilja
Silani, Yaser
Richards, Bryan A.
Berzins, Andris
Aiello, Maxwell D.
Lidke, Keith A.
Jarmola, Andrey
Smits, Janis
Acosta, Victor M.
author_facet Ziabari, Maziar Saleh
Mosavian, Nazanin
Fescenko, Ilja
Silani, Yaser
Richards, Bryan A.
Berzins, Andris
Aiello, Maxwell D.
Lidke, Keith A.
Jarmola, Andrey
Smits, Janis
Acosta, Victor M.
contents Vector magnetometers based on the optically detected magnetic resonance (ODMR) of nitrogen-vacancy centers in diamond are being developed for applications such as navigation and geomagnetism. However, at low magnetic fields, such as that on Earth (~50 μT), diamond magnetometers suffer from spectral congestion whereby ODMR peaks are not easily resolved. Here, we experimentally investigate a potential solution of using an isotropic, three-dimensional magnetic flux concentrator to amplify Earth's field without altering its direction. The concentrator consists of six ferrite cones, in a face-centered cubic arrangement, centered about a diamond. We vary the direction of a 50 μT applied field and record and fit the resulting ODMR spectra. By comparing the fitted fields to those of a reference fluxgate magnetometer, we characterize the angular response of the diamond magnetometer and quantify absolute errors in the field magnitude and angle. We find that the enhancement factor is nearly isotropic, with a mean of 19.05 and a standard deviation of 0.16, when weighted by solid angle coverage. Gradient broadening of the ODMR lines is sufficiently small that the spectra are well resolved for nearly all field directions, alleviating spectral congestion. For ~98% of the total 4π solid angle, Cramér-Rao lower bounds for magnetic field estimation uncertainty are within a factor of 2 of those of the fully-resolved case, indicating minimal deadzones. We track the stability of the magnetometer over six hours and observe variations less than or approximately 40 nT/hour, limited by temperature drift. Our study presents a new route for diamond vector magnetometry at Earth's field, with potential applications in geomagnetic surveys, anomaly detection, and navigation.
format Preprint
id arxiv_https___arxiv_org_abs_2507_00215
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Earth's field diamond vector magnetometry with isotropic magnetic flux concentrators
Ziabari, Maziar Saleh
Mosavian, Nazanin
Fescenko, Ilja
Silani, Yaser
Richards, Bryan A.
Berzins, Andris
Aiello, Maxwell D.
Lidke, Keith A.
Jarmola, Andrey
Smits, Janis
Acosta, Victor M.
Instrumentation and Detectors
Mesoscale and Nanoscale Physics
Applied Physics
Optics
Quantum Physics
Vector magnetometers based on the optically detected magnetic resonance (ODMR) of nitrogen-vacancy centers in diamond are being developed for applications such as navigation and geomagnetism. However, at low magnetic fields, such as that on Earth (~50 μT), diamond magnetometers suffer from spectral congestion whereby ODMR peaks are not easily resolved. Here, we experimentally investigate a potential solution of using an isotropic, three-dimensional magnetic flux concentrator to amplify Earth's field without altering its direction. The concentrator consists of six ferrite cones, in a face-centered cubic arrangement, centered about a diamond. We vary the direction of a 50 μT applied field and record and fit the resulting ODMR spectra. By comparing the fitted fields to those of a reference fluxgate magnetometer, we characterize the angular response of the diamond magnetometer and quantify absolute errors in the field magnitude and angle. We find that the enhancement factor is nearly isotropic, with a mean of 19.05 and a standard deviation of 0.16, when weighted by solid angle coverage. Gradient broadening of the ODMR lines is sufficiently small that the spectra are well resolved for nearly all field directions, alleviating spectral congestion. For ~98% of the total 4π solid angle, Cramér-Rao lower bounds for magnetic field estimation uncertainty are within a factor of 2 of those of the fully-resolved case, indicating minimal deadzones. We track the stability of the magnetometer over six hours and observe variations less than or approximately 40 nT/hour, limited by temperature drift. Our study presents a new route for diamond vector magnetometry at Earth's field, with potential applications in geomagnetic surveys, anomaly detection, and navigation.