Automated anatomy-based post-processing reduces false positives and improved interpretability of deep learning intracranial aneurysm detection

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Kim, Jisoo, Lin, Chu-Hsuan, Ceballos-Arroyo, Alberto, Liu, Ping, Jiang, Huaizu, Yadav, Shrikanth, Wan, Qi, Qin, Lei, Young, Geoffrey S
Format: Preprint
Veröffentlicht: 2025
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866911032046256128
author Kim, Jisoo
Lin, Chu-Hsuan
Ceballos-Arroyo, Alberto
Liu, Ping
Jiang, Huaizu
Yadav, Shrikanth
Wan, Qi
Qin, Lei
Young, Geoffrey S
author_facet Kim, Jisoo
Lin, Chu-Hsuan
Ceballos-Arroyo, Alberto
Liu, Ping
Jiang, Huaizu
Yadav, Shrikanth
Wan, Qi
Qin, Lei
Young, Geoffrey S
contents Introduction: Deep learning (DL) models can help detect intracranial aneurysms on CTA, but high false positive (FP) rates remain a barrier to clinical translation, despite improvement in model architectures and strategies like detection threshold tuning. We employed an automated, anatomy-based, heuristic-learning hybrid artery-vein segmentation post-processing method to further reduce FPs. Methods: Two DL models, CPM-Net and a deformable 3D convolutional neural network-transformer hybrid (3D-CNN-TR), were trained with 1,186 open-source CTAs (1,373 annotated aneurysms), and evaluated with 143 held-out private CTAs (218 annotated aneurysms). Brain, artery, vein, and cavernous venous sinus (CVS) segmentation masks were applied to remove possible FPs in the DL outputs that overlapped with: (1) brain mask; (2) vein mask; (3) vein more than artery masks; (4) brain plus vein mask; (5) brain plus vein more than artery masks. Results: CPM-Net yielded 139 true-positives (TP); 79 false-negative (FN); 126 FP. 3D-CNN-TR yielded 179 TP; 39 FN; 182 FP. FPs were commonly extracranial (CPM-Net 27.3%; 3D-CNN-TR 42.3%), venous (CPM-Net 56.3%; 3D-CNN-TR 29.1%), arterial (CPM-Net 11.9%; 3D-CNN-TR 53.3%), and non-vascular (CPM-Net 25.4%; 3D-CNN-TR 9.3%) structures. Method 5 performed best, reducing CPM-Net FP by 70.6% (89/126) and 3D-CNN-TR FP by 51.6% (94/182), without reducing TP, lowering the FP/case rate from 0.88 to 0.26 for CPM-NET, and from 1.27 to 0.62 for the 3D-CNN-TR. Conclusion: Anatomy-based, interpretable post-processing can improve DL-based aneurysm detection model performance. More broadly, automated, domain-informed, hybrid heuristic-learning processing holds promise for improving the performance and clinical acceptance of aneurysm detection models.
format Preprint
id arxiv_https___arxiv_org_abs_2507_00832
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Automated anatomy-based post-processing reduces false positives and improved interpretability of deep learning intracranial aneurysm detection
Kim, Jisoo
Lin, Chu-Hsuan
Ceballos-Arroyo, Alberto
Liu, Ping
Jiang, Huaizu
Yadav, Shrikanth
Wan, Qi
Qin, Lei
Young, Geoffrey S
Image and Video Processing
Artificial Intelligence
Computer Vision and Pattern Recognition
Introduction: Deep learning (DL) models can help detect intracranial aneurysms on CTA, but high false positive (FP) rates remain a barrier to clinical translation, despite improvement in model architectures and strategies like detection threshold tuning. We employed an automated, anatomy-based, heuristic-learning hybrid artery-vein segmentation post-processing method to further reduce FPs. Methods: Two DL models, CPM-Net and a deformable 3D convolutional neural network-transformer hybrid (3D-CNN-TR), were trained with 1,186 open-source CTAs (1,373 annotated aneurysms), and evaluated with 143 held-out private CTAs (218 annotated aneurysms). Brain, artery, vein, and cavernous venous sinus (CVS) segmentation masks were applied to remove possible FPs in the DL outputs that overlapped with: (1) brain mask; (2) vein mask; (3) vein more than artery masks; (4) brain plus vein mask; (5) brain plus vein more than artery masks. Results: CPM-Net yielded 139 true-positives (TP); 79 false-negative (FN); 126 FP. 3D-CNN-TR yielded 179 TP; 39 FN; 182 FP. FPs were commonly extracranial (CPM-Net 27.3%; 3D-CNN-TR 42.3%), venous (CPM-Net 56.3%; 3D-CNN-TR 29.1%), arterial (CPM-Net 11.9%; 3D-CNN-TR 53.3%), and non-vascular (CPM-Net 25.4%; 3D-CNN-TR 9.3%) structures. Method 5 performed best, reducing CPM-Net FP by 70.6% (89/126) and 3D-CNN-TR FP by 51.6% (94/182), without reducing TP, lowering the FP/case rate from 0.88 to 0.26 for CPM-NET, and from 1.27 to 0.62 for the 3D-CNN-TR. Conclusion: Anatomy-based, interpretable post-processing can improve DL-based aneurysm detection model performance. More broadly, automated, domain-informed, hybrid heuristic-learning processing holds promise for improving the performance and clinical acceptance of aneurysm detection models.
title Automated anatomy-based post-processing reduces false positives and improved interpretability of deep learning intracranial aneurysm detection
topic Image and Video Processing
Artificial Intelligence
Computer Vision and Pattern Recognition
url https://arxiv.org/abs/2507.00832