An accurate measurement of the spectral resolution of the JWST Near Infrared Spectrograph

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Shajib, Anowar J., Treu, Tommaso, Melo, Alejandra, Roberts-Borsani, Guido, Knabel, Shawn, Cappellari, Michele, Frieman, Joshua A.
Natura: Preprint
Pubblicazione: 2025
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866917030045679616
author Shajib, Anowar J.
Treu, Tommaso
Melo, Alejandra
Roberts-Borsani, Guido
Knabel, Shawn
Cappellari, Michele
Frieman, Joshua A.
author_facet Shajib, Anowar J.
Treu, Tommaso
Melo, Alejandra
Roberts-Borsani, Guido
Knabel, Shawn
Cappellari, Michele
Frieman, Joshua A.
contents The spectral resolution ($R \equiv λ/ Δλ$) of spectroscopic data is crucial information for accurate kinematic measurements. In this letter, we present a robust measurement of the spectral resolution of the JWST's Near Infrared Spectrograph (NIRSpec) in fixed slit (FS) and integral field spectroscopy (IFS) modes. Due to the similarity of the utilized slit dimension if the FS mode to that of the shutters in the multi-object spectroscopy (MOS) mode, our resolution measurements in the FS mode can also be used for the MOS mode in principle. We modeled H and He lines of the planetary nebula SMP LMC 58 using a Gaussian line spread function (LSF) to estimate the wavelength-dependent resolution for multiple disperser and filter combinations. We corrected for the intrinsic width of the planetary nebula's H and He lines due to its expansion velocity by measuring it from a higher-resolution X-shooter spectrum. We find that NIRSpec's in-flight spectral resolutions exceed the pre-launch estimates provided in the JWST User Documentation by 11-53% in the FS mode and by 1-24% in the IFS mode across the covered wavelengths. We recover the expected trend that the resolution increases with the wavelength within a configuration. The robust and accurate LSFs presented in this letter will enable high-accuracy kinematic measurements using NIRSpec for applications in cosmology and galaxy evolution.
format Preprint
id arxiv_https___arxiv_org_abs_2507_03746
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle An accurate measurement of the spectral resolution of the JWST Near Infrared Spectrograph
Shajib, Anowar J.
Treu, Tommaso
Melo, Alejandra
Roberts-Borsani, Guido
Knabel, Shawn
Cappellari, Michele
Frieman, Joshua A.
Instrumentation and Methods for Astrophysics
The spectral resolution ($R \equiv λ/ Δλ$) of spectroscopic data is crucial information for accurate kinematic measurements. In this letter, we present a robust measurement of the spectral resolution of the JWST's Near Infrared Spectrograph (NIRSpec) in fixed slit (FS) and integral field spectroscopy (IFS) modes. Due to the similarity of the utilized slit dimension if the FS mode to that of the shutters in the multi-object spectroscopy (MOS) mode, our resolution measurements in the FS mode can also be used for the MOS mode in principle. We modeled H and He lines of the planetary nebula SMP LMC 58 using a Gaussian line spread function (LSF) to estimate the wavelength-dependent resolution for multiple disperser and filter combinations. We corrected for the intrinsic width of the planetary nebula's H and He lines due to its expansion velocity by measuring it from a higher-resolution X-shooter spectrum. We find that NIRSpec's in-flight spectral resolutions exceed the pre-launch estimates provided in the JWST User Documentation by 11-53% in the FS mode and by 1-24% in the IFS mode across the covered wavelengths. We recover the expected trend that the resolution increases with the wavelength within a configuration. The robust and accurate LSFs presented in this letter will enable high-accuracy kinematic measurements using NIRSpec for applications in cosmology and galaxy evolution.
title An accurate measurement of the spectral resolution of the JWST Near Infrared Spectrograph
topic Instrumentation and Methods for Astrophysics
url https://arxiv.org/abs/2507.03746