Muon Signal Charge in the Underground Muon Detector of AugerPrime

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
1. Verfasser: Scornavacche, Marina
Format: Preprint
Veröffentlicht: 2025
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866916860467871744
author Scornavacche, Marina
author_facet Scornavacche, Marina
contents The Underground Muon Detector of the Pierre Auger Observatory features a calorimetric detection mode that estimates the number of muons based on signal charge measurements. This contribution provides an overview of the calibration procedure, revisiting the previously published strategy and identifying a bias introduced by the triggers used to estimate the mean charge deposited by a vertical muon. We demonstrate that calibrating underground detectors requires careful consideration of the interactions of penetrating particles through matter. In devices based on plastic scintillators, energy deposition, and thus the recorded charge, is significantly affected by knock-on electron production in the surrounding ground as muons traverse the medium. To mitigate this effect, we propose a new calibration strategy that ensures an unbiased muon estimator. This approach is applied to data collected from 2019 to 2024.
format Preprint
id arxiv_https___arxiv_org_abs_2507_09006
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Muon Signal Charge in the Underground Muon Detector of AugerPrime
Scornavacche, Marina
Instrumentation and Detectors
Instrumentation and Methods for Astrophysics
High Energy Physics - Phenomenology
The Underground Muon Detector of the Pierre Auger Observatory features a calorimetric detection mode that estimates the number of muons based on signal charge measurements. This contribution provides an overview of the calibration procedure, revisiting the previously published strategy and identifying a bias introduced by the triggers used to estimate the mean charge deposited by a vertical muon. We demonstrate that calibrating underground detectors requires careful consideration of the interactions of penetrating particles through matter. In devices based on plastic scintillators, energy deposition, and thus the recorded charge, is significantly affected by knock-on electron production in the surrounding ground as muons traverse the medium. To mitigate this effect, we propose a new calibration strategy that ensures an unbiased muon estimator. This approach is applied to data collected from 2019 to 2024.
title Muon Signal Charge in the Underground Muon Detector of AugerPrime
topic Instrumentation and Detectors
Instrumentation and Methods for Astrophysics
High Energy Physics - Phenomenology
url https://arxiv.org/abs/2507.09006