The calibration house in JUNO

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Hui, J., Li, R., Wu, Y., Zhang, T., Chen, Z., Freegard, A., Huang, J., Lai, H., Liao, Y., Liu, J., Meng, Y., Takenaka, A., Xiang, Z., Zhang, P., Zhang, Y.
Format: Preprint
Veröffentlicht: 2025
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866909686572253184
author Hui, J.
Li, R.
Wu, Y.
Zhang, T.
Chen, Z.
Freegard, A.
Huang, J.
Lai, H.
Liao, Y.
Liu, J.
Meng, Y.
Takenaka, A.
Xiang, Z.
Zhang, P.
Zhang, Y.
author_facet Hui, J.
Li, R.
Wu, Y.
Zhang, T.
Chen, Z.
Freegard, A.
Huang, J.
Lai, H.
Liao, Y.
Liu, J.
Meng, Y.
Takenaka, A.
Xiang, Z.
Zhang, P.
Zhang, Y.
contents As an auxiliary system within the calibration system of the Jiangmen Underground Neutrino Observatory, a calibration house is designed to provide interfaces for connecting the central detector and accommodating various calibration sub-systems. Onsite installation has demonstrated that the calibration house interfaces are capable of effectively connecting to the central detector and supporting the installation of complex and sophisticated calibration sub-systems. Additionally, controlling the levels of radon and oxygen within the calibration house is critical. Radon can increase the experimental background, while oxygen can degrade the quality of the liquid scintillator. The oxygen concentration can be maintained at levels below 10 parts per million, and the radon concentration can be kept below 15 mBq/m$^{3}$. This paper will provide detailed information on the calibration house and its methods for radon and oxygen concentration control.
format Preprint
id arxiv_https___arxiv_org_abs_2507_09208
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle The calibration house in JUNO
Hui, J.
Li, R.
Wu, Y.
Zhang, T.
Chen, Z.
Freegard, A.
Huang, J.
Lai, H.
Liao, Y.
Liu, J.
Meng, Y.
Takenaka, A.
Xiang, Z.
Zhang, P.
Zhang, Y.
Instrumentation and Detectors
High Energy Physics - Experiment
As an auxiliary system within the calibration system of the Jiangmen Underground Neutrino Observatory, a calibration house is designed to provide interfaces for connecting the central detector and accommodating various calibration sub-systems. Onsite installation has demonstrated that the calibration house interfaces are capable of effectively connecting to the central detector and supporting the installation of complex and sophisticated calibration sub-systems. Additionally, controlling the levels of radon and oxygen within the calibration house is critical. Radon can increase the experimental background, while oxygen can degrade the quality of the liquid scintillator. The oxygen concentration can be maintained at levels below 10 parts per million, and the radon concentration can be kept below 15 mBq/m$^{3}$. This paper will provide detailed information on the calibration house and its methods for radon and oxygen concentration control.
title The calibration house in JUNO
topic Instrumentation and Detectors
High Energy Physics - Experiment
url https://arxiv.org/abs/2507.09208