Calibration and Performance of the Surface Scintillator Detector of the Pierre Auger Observatory

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autore principale: Conte, M.
Natura: Preprint
Pubblicazione: 2025
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866909698334130176
author Conte, M.
author_facet Conte, M.
contents The Pierre Auger Observatory has led to significant advances in our understanding of ultra-high-energy cosmic rays. These new insights have driven a major upgrade of the Observatory, known as AugerPrime, through which the experiment has entered its Phase II, a new period of data collection. A key part of the upgrade is adding surface scintillator detectors (SSD) on top of the existing water-Cherenkov detectors (WCD). The main goal is to leverage their different responses to the electromagnetic and muonic shower components, enhancing the reconstruction of the primary cosmic-ray mass. In this contribution, we present the methods that involve analyzing peak and charge distributions of atmospheric muons for accurate calibration during extensive air-shower event reconstruction, along with the development of a rate-based algorithm for independent calibration. We also show the performance of the SSDs with Phase-II data, including PMT reliability and stability of key parameters, such as gain and signal-to-noise ratio.
format Preprint
id arxiv_https___arxiv_org_abs_2507_09221
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Calibration and Performance of the Surface Scintillator Detector of the Pierre Auger Observatory
Conte, M.
Instrumentation and Methods for Astrophysics
High Energy Astrophysical Phenomena
Instrumentation and Detectors
The Pierre Auger Observatory has led to significant advances in our understanding of ultra-high-energy cosmic rays. These new insights have driven a major upgrade of the Observatory, known as AugerPrime, through which the experiment has entered its Phase II, a new period of data collection. A key part of the upgrade is adding surface scintillator detectors (SSD) on top of the existing water-Cherenkov detectors (WCD). The main goal is to leverage their different responses to the electromagnetic and muonic shower components, enhancing the reconstruction of the primary cosmic-ray mass. In this contribution, we present the methods that involve analyzing peak and charge distributions of atmospheric muons for accurate calibration during extensive air-shower event reconstruction, along with the development of a rate-based algorithm for independent calibration. We also show the performance of the SSDs with Phase-II data, including PMT reliability and stability of key parameters, such as gain and signal-to-noise ratio.
title Calibration and Performance of the Surface Scintillator Detector of the Pierre Auger Observatory
topic Instrumentation and Methods for Astrophysics
High Energy Astrophysical Phenomena
Instrumentation and Detectors
url https://arxiv.org/abs/2507.09221