Performance of newly constructed plastic scintillator barrel in the WASA-FRS experiments and evaluation of radiation damage effects on multi-pixel photon counter
Fuente:
arXiv
Saved in:
| Main Authors: | , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , |
|---|---|
| Format: | Preprint |
| Published: |
2025
|
| Subjects: | |
| Online Access: | |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1866912481893416960 |
|---|---|
| author | Tanaka, Y. K. Sekiya, R. Itahashi, K. Alfaki, H. Alibrahim Amjad, F. Armstrong, M. Behr, K. -H. Benlliure, J. Brencic, Z. Dickel, T. Drozd, V. Dubey, S. Ekawa, H. Escrig, S. Feijoo-Fontán, M. Fujioka, H. Gao, Y. Geissel, H. Goldenbaum, F. González, A. Graña Haettner, E. Harakeh, M. N. He, Y. Heggen, H. Hornung, C. Hubbard, N. Iwasaki, M. Kalantar-Nayestanaki, N. Kasagi, A. Kavatsyuk, M. Kazantseva, E. Khreptak, A. Kindler, B. Kollmus, H. Kostyleva, D. Kraft-Bermuth, S. Kurz, N. Liu, E. Lommel, B. Minami, S. Morrissey, D. J. Moskal, P. Mukha, I. Nakagawa, M. Nociforo, C. Ong, H. J. Pietri, S. Purushothaman, S. Rappold, C. Rocco, E. Rodríguez-Sánchez, J. L. Roy, P. Ruber, R. Saito, T. R. Schadmand, S. Scheidenberger, C. Schwarz, P. Serdyuk, V. Skurzok, M. Streicher, B. Suzuki, K. Szczepanczyk, B. Tang, X. Tortorelli, N. Vencelj, M. Weber, T. Weick, H. Will, M. Wimmer, K. Yamamoto, A. Yanai, A. Zhao, J. Collaboration, for WASA-FRS/Super-FRS Experiment |
| author_facet | Tanaka, Y. K. Sekiya, R. Itahashi, K. Alfaki, H. Alibrahim Amjad, F. Armstrong, M. Behr, K. -H. Benlliure, J. Brencic, Z. Dickel, T. Drozd, V. Dubey, S. Ekawa, H. Escrig, S. Feijoo-Fontán, M. Fujioka, H. Gao, Y. Geissel, H. Goldenbaum, F. González, A. Graña Haettner, E. Harakeh, M. N. He, Y. Heggen, H. Hornung, C. Hubbard, N. Iwasaki, M. Kalantar-Nayestanaki, N. Kasagi, A. Kavatsyuk, M. Kazantseva, E. Khreptak, A. Kindler, B. Kollmus, H. Kostyleva, D. Kraft-Bermuth, S. Kurz, N. Liu, E. Lommel, B. Minami, S. Morrissey, D. J. Moskal, P. Mukha, I. Nakagawa, M. Nociforo, C. Ong, H. J. Pietri, S. Purushothaman, S. Rappold, C. Rocco, E. Rodríguez-Sánchez, J. L. Roy, P. Ruber, R. Saito, T. R. Schadmand, S. Scheidenberger, C. Schwarz, P. Serdyuk, V. Skurzok, M. Streicher, B. Suzuki, K. Szczepanczyk, B. Tang, X. Tortorelli, N. Vencelj, M. Weber, T. Weick, H. Will, M. Wimmer, K. Yamamoto, A. Yanai, A. Zhao, J. Collaboration, for WASA-FRS/Super-FRS Experiment |
| contents | A barrel-shaped plastic scintillation counter with Multi-Pixel Photon Counter (MPPC) readout has been developed and operated in the first WASA-FRS experimental campaign at GSI. The detector was used to measure charged particles emitted from reactions induced by a 2.5 GeV proton beam incident on a carbon target, providing particle identification in combination with momentum reconstruction in a 1 T magnetic field. The performance of this detector, particularly its response to energy deposition and time resolution, was systematically investigated as a function of count rate and total number of irradiating protons. A time resolution of 45-75 ps ($σ$), depending on the energy deposition, was achieved. Stable performance was maintained under high-rate conditions up to 1.35 MHz per single counter, with no significant degradation in either signal amplitude or timing response. Radiation-induced damage to the MPPCs was observed primarily as a reduction in signal amplitude, with approximately $35\%$ decrease at an estimated 1 MeV neutron-equivalent fluence of $2.4 \times 10^{10}$ cm$^{-2}$. |
| format | Preprint |
| id |
arxiv_https___arxiv_org_abs_2507_10454 |
| institution | arXiv |
| publishDate | 2025 |
| record_format | arxiv |
| spellingShingle | Performance of newly constructed plastic scintillator barrel in the WASA-FRS experiments and evaluation of radiation damage effects on multi-pixel photon counter Tanaka, Y. K. Sekiya, R. Itahashi, K. Alfaki, H. Alibrahim Amjad, F. Armstrong, M. Behr, K. -H. Benlliure, J. Brencic, Z. Dickel, T. Drozd, V. Dubey, S. Ekawa, H. Escrig, S. Feijoo-Fontán, M. Fujioka, H. Gao, Y. Geissel, H. Goldenbaum, F. González, A. Graña Haettner, E. Harakeh, M. N. He, Y. Heggen, H. Hornung, C. Hubbard, N. Iwasaki, M. Kalantar-Nayestanaki, N. Kasagi, A. Kavatsyuk, M. Kazantseva, E. Khreptak, A. Kindler, B. Kollmus, H. Kostyleva, D. Kraft-Bermuth, S. Kurz, N. Liu, E. Lommel, B. Minami, S. Morrissey, D. J. Moskal, P. Mukha, I. Nakagawa, M. Nociforo, C. Ong, H. J. Pietri, S. Purushothaman, S. Rappold, C. Rocco, E. Rodríguez-Sánchez, J. L. Roy, P. Ruber, R. Saito, T. R. Schadmand, S. Scheidenberger, C. Schwarz, P. Serdyuk, V. Skurzok, M. Streicher, B. Suzuki, K. Szczepanczyk, B. Tang, X. Tortorelli, N. Vencelj, M. Weber, T. Weick, H. Will, M. Wimmer, K. Yamamoto, A. Yanai, A. Zhao, J. Collaboration, for WASA-FRS/Super-FRS Experiment Instrumentation and Detectors Nuclear Experiment A barrel-shaped plastic scintillation counter with Multi-Pixel Photon Counter (MPPC) readout has been developed and operated in the first WASA-FRS experimental campaign at GSI. The detector was used to measure charged particles emitted from reactions induced by a 2.5 GeV proton beam incident on a carbon target, providing particle identification in combination with momentum reconstruction in a 1 T magnetic field. The performance of this detector, particularly its response to energy deposition and time resolution, was systematically investigated as a function of count rate and total number of irradiating protons. A time resolution of 45-75 ps ($σ$), depending on the energy deposition, was achieved. Stable performance was maintained under high-rate conditions up to 1.35 MHz per single counter, with no significant degradation in either signal amplitude or timing response. Radiation-induced damage to the MPPCs was observed primarily as a reduction in signal amplitude, with approximately $35\%$ decrease at an estimated 1 MeV neutron-equivalent fluence of $2.4 \times 10^{10}$ cm$^{-2}$. |
| title | Performance of newly constructed plastic scintillator barrel in the WASA-FRS experiments and evaluation of radiation damage effects on multi-pixel photon counter |
| topic | Instrumentation and Detectors Nuclear Experiment |
| url | https://arxiv.org/abs/2507.10454 |