Digital defocus aberration interference for automated optical microscopy

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Zhou, Haowen, Zhao, Shi, Fan, Yujie, Dong, Zhenyu, Zhang, Oumeng, Gradinaru, Viviana, Yang, Changhuei
Format: Preprint
Published: 2025
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866911457648574464
author Zhou, Haowen
Zhao, Shi
Fan, Yujie
Dong, Zhenyu
Zhang, Oumeng
Gradinaru, Viviana
Yang, Changhuei
author_facet Zhou, Haowen
Zhao, Shi
Fan, Yujie
Dong, Zhenyu
Zhang, Oumeng
Gradinaru, Viviana
Yang, Changhuei
contents Automation in optical microscopy is critical for enabling high-throughput imaging across a wide range of biomedical applications. Among the essential components of automated systems, robust autofocusing plays a pivotal role in maintaining image quality for both single-plane and volumetric imaging. However, conventional autofocusing methods often struggle with implementation complexity, limited generalizability across sample types, incompatibility with thick specimens, and slow feedback. We observed that the digitally summed Fourier spectrum of two images acquired from two-angle illumination exhibits interference-like fringe modulation when the sample is defocused. These digital fringes correlate directly with defocus through a physics-based relation. Based on this principle, we developed an automatic, efficient, and generalizable defocus detection method termed digital defocus aberration interference (DAbI). Implemented with a simple two-LED setup, DAbI can quantify the defocus distance over a range of 443 times the depth-of-field (DoF) for thin samples and 296 times for thick specimens. It can additionally extend the natural DoF of the imaging system by 20 folds when integrated with complex-field imaging. We demonstrated the versatile applications of DAbI on brightfield, complex-field, refractive index, confocal, and widefield fluorescence imaging, establishing it as a promising solution for automated, high-throughput optical microscopy.
format Preprint
id arxiv_https___arxiv_org_abs_2507_10867
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Digital defocus aberration interference for automated optical microscopy
Zhou, Haowen
Zhao, Shi
Fan, Yujie
Dong, Zhenyu
Zhang, Oumeng
Gradinaru, Viviana
Yang, Changhuei
Optics
Automation in optical microscopy is critical for enabling high-throughput imaging across a wide range of biomedical applications. Among the essential components of automated systems, robust autofocusing plays a pivotal role in maintaining image quality for both single-plane and volumetric imaging. However, conventional autofocusing methods often struggle with implementation complexity, limited generalizability across sample types, incompatibility with thick specimens, and slow feedback. We observed that the digitally summed Fourier spectrum of two images acquired from two-angle illumination exhibits interference-like fringe modulation when the sample is defocused. These digital fringes correlate directly with defocus through a physics-based relation. Based on this principle, we developed an automatic, efficient, and generalizable defocus detection method termed digital defocus aberration interference (DAbI). Implemented with a simple two-LED setup, DAbI can quantify the defocus distance over a range of 443 times the depth-of-field (DoF) for thin samples and 296 times for thick specimens. It can additionally extend the natural DoF of the imaging system by 20 folds when integrated with complex-field imaging. We demonstrated the versatile applications of DAbI on brightfield, complex-field, refractive index, confocal, and widefield fluorescence imaging, establishing it as a promising solution for automated, high-throughput optical microscopy.
title Digital defocus aberration interference for automated optical microscopy
topic Optics
url https://arxiv.org/abs/2507.10867