AortaDiff: Volume-Guided Conditional Diffusion Models for Multi-Branch Aortic Surface Generation

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: An, Delin, Du, Pan, Wang, Jian-Xun, Wang, Chaoli
Natura: Preprint
Pubblicazione: 2025
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866913948384624640
author An, Delin
Du, Pan
Wang, Jian-Xun
Wang, Chaoli
author_facet An, Delin
Du, Pan
Wang, Jian-Xun
Wang, Chaoli
contents Accurate 3D aortic construction is crucial for clinical diagnosis, preoperative planning, and computational fluid dynamics (CFD) simulations, as it enables the estimation of critical hemodynamic parameters such as blood flow velocity, pressure distribution, and wall shear stress. Existing construction methods often rely on large annotated training datasets and extensive manual intervention. While the resulting meshes can serve for visualization purposes, they struggle to produce geometrically consistent, well-constructed surfaces suitable for downstream CFD analysis. To address these challenges, we introduce AortaDiff, a diffusion-based framework that generates smooth aortic surfaces directly from CT/MRI volumes. AortaDiff first employs a volume-guided conditional diffusion model (CDM) to iteratively generate aortic centerlines conditioned on volumetric medical images. Each centerline point is then automatically used as a prompt to extract the corresponding vessel contour, ensuring accurate boundary delineation. Finally, the extracted contours are fitted into a smooth 3D surface, yielding a continuous, CFD-compatible mesh representation. AortaDiff offers distinct advantages over existing methods, including an end-to-end workflow, minimal dependency on large labeled datasets, and the ability to generate CFD-compatible aorta meshes with high geometric fidelity. Experimental results demonstrate that AortaDiff performs effectively even with limited training data, successfully constructing both normal and pathologically altered aorta meshes, including cases with aneurysms or coarctation. This capability enables the generation of high-quality visualizations and positions AortaDiff as a practical solution for cardiovascular research.
format Preprint
id arxiv_https___arxiv_org_abs_2507_13404
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle AortaDiff: Volume-Guided Conditional Diffusion Models for Multi-Branch Aortic Surface Generation
An, Delin
Du, Pan
Wang, Jian-Xun
Wang, Chaoli
Computer Vision and Pattern Recognition
Accurate 3D aortic construction is crucial for clinical diagnosis, preoperative planning, and computational fluid dynamics (CFD) simulations, as it enables the estimation of critical hemodynamic parameters such as blood flow velocity, pressure distribution, and wall shear stress. Existing construction methods often rely on large annotated training datasets and extensive manual intervention. While the resulting meshes can serve for visualization purposes, they struggle to produce geometrically consistent, well-constructed surfaces suitable for downstream CFD analysis. To address these challenges, we introduce AortaDiff, a diffusion-based framework that generates smooth aortic surfaces directly from CT/MRI volumes. AortaDiff first employs a volume-guided conditional diffusion model (CDM) to iteratively generate aortic centerlines conditioned on volumetric medical images. Each centerline point is then automatically used as a prompt to extract the corresponding vessel contour, ensuring accurate boundary delineation. Finally, the extracted contours are fitted into a smooth 3D surface, yielding a continuous, CFD-compatible mesh representation. AortaDiff offers distinct advantages over existing methods, including an end-to-end workflow, minimal dependency on large labeled datasets, and the ability to generate CFD-compatible aorta meshes with high geometric fidelity. Experimental results demonstrate that AortaDiff performs effectively even with limited training data, successfully constructing both normal and pathologically altered aorta meshes, including cases with aneurysms or coarctation. This capability enables the generation of high-quality visualizations and positions AortaDiff as a practical solution for cardiovascular research.
title AortaDiff: Volume-Guided Conditional Diffusion Models for Multi-Branch Aortic Surface Generation
topic Computer Vision and Pattern Recognition
url https://arxiv.org/abs/2507.13404