Quantifying Key Design Factors for Thermal Comfort in Underground Space Through Global Sensitivity Analysis and Machine Learning

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Chen, Shisheng, Wong, Nyuk Hien, Cen, Chao, Xu, Ruohan, Xu, Lei, Shen, Zhenjiang, Wu, Zhigang, Fu, Jiayan, Yu, Zhongqi
Format: Preprint
Publié: 2025
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866909921147092992
author Chen, Shisheng
Wong, Nyuk Hien
Cen, Chao
Xu, Ruohan
Xu, Lei
Shen, Zhenjiang
Wu, Zhigang
Fu, Jiayan
Yu, Zhongqi
author_facet Chen, Shisheng
Wong, Nyuk Hien
Cen, Chao
Xu, Ruohan
Xu, Lei
Shen, Zhenjiang
Wu, Zhigang
Fu, Jiayan
Yu, Zhongqi
contents This study identified the key design factors related to thermal comfort in naturally ventilated underground spaces under high temperature conditions (outdoor Tmax = 42.9 C) in Fuzhou, China. Fuzhou has a humid subtropical climate and is one of the three hottest cities in China in 2024. Daytime measurements indicated reduced air temperature (AT), mean radiant temperature (MRT), and wind speed (V), together with elevated relative humidity (RH) in the underground space. Physiological Equivalent Temperature (PET) in the underground was consistently lower during peak hours (08:00-16:00), with the maximum difference in PET between pedestrian and underground levels being 11-11.9 C. Higher pedestrian-level PET at L1 was attributed to reduced greenery and shading, and decrement factors indicated greater thermal dampening at L2 (0.197) than at L1 (0.308). Sensitivity analysis showed that MRT was the most influential factor (S1/ST = 0.59-0.72) for aboveground spaces, followed by AT (0.13-0.26). In contrast, underground PET was mainly affected by metabolic rate (MET) (0.63-0.65), followed by RH (0.14-0.20) and V (0.08-0.18). Partial dependence analysis revealed that a 1 met increase in MET raised PET by 1.6 C, whereas a 1 m/s increase in V reduced PET by 1.5-2.2 C in the underground space. Due to cooler and more stable thermal conditions, underground spaces have higher tolerance for intensive physical activities. By buffering fluctuations in AT and MRT, underground environments can significantly alleviate heat stress and provide passive cooling shelter during daytime heat waves. Overall, this study provides empirical evidence to support underground space design in hot-humid climates and offers insights for sustainable urban heat mitigation.
format Preprint
id arxiv_https___arxiv_org_abs_2507_16202
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Quantifying Key Design Factors for Thermal Comfort in Underground Space Through Global Sensitivity Analysis and Machine Learning
Chen, Shisheng
Wong, Nyuk Hien
Cen, Chao
Xu, Ruohan
Xu, Lei
Shen, Zhenjiang
Wu, Zhigang
Fu, Jiayan
Yu, Zhongqi
Applied Physics
This study identified the key design factors related to thermal comfort in naturally ventilated underground spaces under high temperature conditions (outdoor Tmax = 42.9 C) in Fuzhou, China. Fuzhou has a humid subtropical climate and is one of the three hottest cities in China in 2024. Daytime measurements indicated reduced air temperature (AT), mean radiant temperature (MRT), and wind speed (V), together with elevated relative humidity (RH) in the underground space. Physiological Equivalent Temperature (PET) in the underground was consistently lower during peak hours (08:00-16:00), with the maximum difference in PET between pedestrian and underground levels being 11-11.9 C. Higher pedestrian-level PET at L1 was attributed to reduced greenery and shading, and decrement factors indicated greater thermal dampening at L2 (0.197) than at L1 (0.308). Sensitivity analysis showed that MRT was the most influential factor (S1/ST = 0.59-0.72) for aboveground spaces, followed by AT (0.13-0.26). In contrast, underground PET was mainly affected by metabolic rate (MET) (0.63-0.65), followed by RH (0.14-0.20) and V (0.08-0.18). Partial dependence analysis revealed that a 1 met increase in MET raised PET by 1.6 C, whereas a 1 m/s increase in V reduced PET by 1.5-2.2 C in the underground space. Due to cooler and more stable thermal conditions, underground spaces have higher tolerance for intensive physical activities. By buffering fluctuations in AT and MRT, underground environments can significantly alleviate heat stress and provide passive cooling shelter during daytime heat waves. Overall, this study provides empirical evidence to support underground space design in hot-humid climates and offers insights for sustainable urban heat mitigation.
title Quantifying Key Design Factors for Thermal Comfort in Underground Space Through Global Sensitivity Analysis and Machine Learning
topic Applied Physics
url https://arxiv.org/abs/2507.16202