Yield, noise and timing studies of ALICE ITS3 stitched sensor test structures: the MOST

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Sonneveld, Jory, Barthel, René, Bugiel, Szymon, Cecconi, Leonardo, De Melo, João, Fransen, Martin, Grelli, Alessandro, Hobus, Isis, Isakov, Artem, Junique, Antoine, Leitao, Pedro, Mager, Magnus, Otarid, Younes, Piro, Francesco, Rossewij, Marcel, Selina, Mariia, Solokhin, Sergei, Snoeys, Walter, Tiltmann, Nicolas, Vitkovskiy, Arseniy, Wennlöf, Håkan
Formato: Preprint
Publicado: 2025
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866918101669380096
author Sonneveld, Jory
Barthel, René
Bugiel, Szymon
Cecconi, Leonardo
De Melo, João
Fransen, Martin
Grelli, Alessandro
Hobus, Isis
Isakov, Artem
Junique, Antoine
Leitao, Pedro
Mager, Magnus
Otarid, Younes
Piro, Francesco
Rossewij, Marcel
Selina, Mariia
Solokhin, Sergei
Snoeys, Walter
Tiltmann, Nicolas
Vitkovskiy, Arseniy
Wennlöf, Håkan
author_facet Sonneveld, Jory
Barthel, René
Bugiel, Szymon
Cecconi, Leonardo
De Melo, João
Fransen, Martin
Grelli, Alessandro
Hobus, Isis
Isakov, Artem
Junique, Antoine
Leitao, Pedro
Mager, Magnus
Otarid, Younes
Piro, Francesco
Rossewij, Marcel
Selina, Mariia
Solokhin, Sergei
Snoeys, Walter
Tiltmann, Nicolas
Vitkovskiy, Arseniy
Wennlöf, Håkan
contents In the LHC long shutdown 3, the ALICE experiment upgrades the inner layers of its Inner Tracker System with three layers of wafer-scale stitched sensors bent around the beam pipe. Two stitched sensor evaluation structures, the MOnolithic Stitched Sensor (MOSS) and MOnolithic Stitched Sensor with Timing (MOST) allow the study of yield dependence on circuit density, power supply segmentation, stitching demonstration for power and data transmission, performance dependence on reverse bias, charge collection performance, parameter uniformity across the chip, and performance of wafer-scale data transmission. The MOST measures 25.9 cm x 0.25 cm, has more than 900,000 pixels of 18x18 $μ$m$^2$ and emphasizes the validation of pixel circuitry with maximum density, together with a high number of power domains separated by switches allowing to disconnect faulty circuits. It employs 1 Gb/s 26 cm long data transmission using asynchronous, data-driven readout. This readout preserves information on pixel address, time of arrival and time over threshold. In the MOSS, by contrast, regions with different in-pixel densities are implemented to study yield dependence and are read synchronously. MOST test results validated the concept of power domain switching and the data transmission over 26 cm stitched lines which are to be employed on the full-size, full-functionality ITS3 prototype sensor, MOSAIX. Jitter of this transmission is still under study. This proceeding summarizes the performance of the stitched sensor test structures with emphasis on the MOST.
format Preprint
id arxiv_https___arxiv_org_abs_2507_16409
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle Yield, noise and timing studies of ALICE ITS3 stitched sensor test structures: the MOST
Sonneveld, Jory
Barthel, René
Bugiel, Szymon
Cecconi, Leonardo
De Melo, João
Fransen, Martin
Grelli, Alessandro
Hobus, Isis
Isakov, Artem
Junique, Antoine
Leitao, Pedro
Mager, Magnus
Otarid, Younes
Piro, Francesco
Rossewij, Marcel
Selina, Mariia
Solokhin, Sergei
Snoeys, Walter
Tiltmann, Nicolas
Vitkovskiy, Arseniy
Wennlöf, Håkan
Instrumentation and Detectors
In the LHC long shutdown 3, the ALICE experiment upgrades the inner layers of its Inner Tracker System with three layers of wafer-scale stitched sensors bent around the beam pipe. Two stitched sensor evaluation structures, the MOnolithic Stitched Sensor (MOSS) and MOnolithic Stitched Sensor with Timing (MOST) allow the study of yield dependence on circuit density, power supply segmentation, stitching demonstration for power and data transmission, performance dependence on reverse bias, charge collection performance, parameter uniformity across the chip, and performance of wafer-scale data transmission. The MOST measures 25.9 cm x 0.25 cm, has more than 900,000 pixels of 18x18 $μ$m$^2$ and emphasizes the validation of pixel circuitry with maximum density, together with a high number of power domains separated by switches allowing to disconnect faulty circuits. It employs 1 Gb/s 26 cm long data transmission using asynchronous, data-driven readout. This readout preserves information on pixel address, time of arrival and time over threshold. In the MOSS, by contrast, regions with different in-pixel densities are implemented to study yield dependence and are read synchronously. MOST test results validated the concept of power domain switching and the data transmission over 26 cm stitched lines which are to be employed on the full-size, full-functionality ITS3 prototype sensor, MOSAIX. Jitter of this transmission is still under study. This proceeding summarizes the performance of the stitched sensor test structures with emphasis on the MOST.
title Yield, noise and timing studies of ALICE ITS3 stitched sensor test structures: the MOST
topic Instrumentation and Detectors
url https://arxiv.org/abs/2507.16409