A multi-dynamic low-rank deep image prior (ML-DIP) for 3D real-time cardiovascular MRI
Fuente:
arXiv
Gespeichert in:
| Hauptverfasser: | , , , , , , , , |
|---|---|
| Format: | Preprint |
| Veröffentlicht: |
2025
|
| Schlagworte: | |
| Online-Zugang: | |
| Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
| _version_ | 1866915655315357696 |
|---|---|
| author | Chen, Chong Vornehm, Marc Bu, Zhenyu Chandrasekaran, Preethi Sultan, Muhammad A. Arshad, Syed M. Liu, Yingmin Han, Yuchi Ahmad, Rizwan |
| author_facet | Chen, Chong Vornehm, Marc Bu, Zhenyu Chandrasekaran, Preethi Sultan, Muhammad A. Arshad, Syed M. Liu, Yingmin Han, Yuchi Ahmad, Rizwan |
| contents | Purpose: To develop a reconstruction framework for 3D real-time cine cardiovascular magnetic resonance (CMR) from highly undersampled data without requiring fully sampled training datasets.
Methods: We developed a multi-dynamic low-rank deep image prior (ML-DIP) framework that models spatial image content and deformation fields using separate neural networks. These sub-networks are jointly trained per scan to reconstruct the dynamic image series directly from undersampled k-space data. ML-DIP was evaluated on (i) a 3D cine digital phantom with simulated premature ventricular contractions (PVCs), (ii) ten healthy subjects (including two scanned during both rest and exercise), and (iii) 12 patients with a history of PVCs. Phantom results were assessed using peak signal-to-noise ratio (PSNR) and structural similarity index measure (SSIM). In vivo performance was evaluated by comparing left-ventricular function quantification (against 2D real-time cine) and image quality (against 2D real-time cine and binning-based 5D-Cine).
Results: In the phantom study, ML-DIP achieved PSNR > 29 dB and SSIM > 0.90 for scan times as short as two minutes, while recovering cardiac motion, respiratory motion, and PVC events. In healthy subjects, ML-DIP yielded functional measurements comparable to 2D cine and higher image quality than 5D-Cine, including during exercise with high heart rates and bulk motion. In PVC patients, ML-DIP preserved beat-to-beat variability and reconstructed irregular beats, whereas 5D-Cine showed motion artifacts and information loss due to binning.
Conclusion: ML-DIP enables high-quality 3D real-time CMR with acceleration factors exceeding 1,000 by learning low-rank spatial and motion representations from undersampled data, without relying on external fully sampled training datasets. |
| format | Preprint |
| id |
arxiv_https___arxiv_org_abs_2507_19404 |
| institution | arXiv |
| publishDate | 2025 |
| record_format | arxiv |
| spellingShingle | A multi-dynamic low-rank deep image prior (ML-DIP) for 3D real-time cardiovascular MRI Chen, Chong Vornehm, Marc Bu, Zhenyu Chandrasekaran, Preethi Sultan, Muhammad A. Arshad, Syed M. Liu, Yingmin Han, Yuchi Ahmad, Rizwan Image and Video Processing Purpose: To develop a reconstruction framework for 3D real-time cine cardiovascular magnetic resonance (CMR) from highly undersampled data without requiring fully sampled training datasets. Methods: We developed a multi-dynamic low-rank deep image prior (ML-DIP) framework that models spatial image content and deformation fields using separate neural networks. These sub-networks are jointly trained per scan to reconstruct the dynamic image series directly from undersampled k-space data. ML-DIP was evaluated on (i) a 3D cine digital phantom with simulated premature ventricular contractions (PVCs), (ii) ten healthy subjects (including two scanned during both rest and exercise), and (iii) 12 patients with a history of PVCs. Phantom results were assessed using peak signal-to-noise ratio (PSNR) and structural similarity index measure (SSIM). In vivo performance was evaluated by comparing left-ventricular function quantification (against 2D real-time cine) and image quality (against 2D real-time cine and binning-based 5D-Cine). Results: In the phantom study, ML-DIP achieved PSNR > 29 dB and SSIM > 0.90 for scan times as short as two minutes, while recovering cardiac motion, respiratory motion, and PVC events. In healthy subjects, ML-DIP yielded functional measurements comparable to 2D cine and higher image quality than 5D-Cine, including during exercise with high heart rates and bulk motion. In PVC patients, ML-DIP preserved beat-to-beat variability and reconstructed irregular beats, whereas 5D-Cine showed motion artifacts and information loss due to binning. Conclusion: ML-DIP enables high-quality 3D real-time CMR with acceleration factors exceeding 1,000 by learning low-rank spatial and motion representations from undersampled data, without relying on external fully sampled training datasets. |
| title | A multi-dynamic low-rank deep image prior (ML-DIP) for 3D real-time cardiovascular MRI |
| topic | Image and Video Processing |
| url | https://arxiv.org/abs/2507.19404 |