A multi-dynamic low-rank deep image prior (ML-DIP) for 3D real-time cardiovascular MRI

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Chen, Chong, Vornehm, Marc, Bu, Zhenyu, Chandrasekaran, Preethi, Sultan, Muhammad A., Arshad, Syed M., Liu, Yingmin, Han, Yuchi, Ahmad, Rizwan
Format: Preprint
Veröffentlicht: 2025
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866915655315357696
author Chen, Chong
Vornehm, Marc
Bu, Zhenyu
Chandrasekaran, Preethi
Sultan, Muhammad A.
Arshad, Syed M.
Liu, Yingmin
Han, Yuchi
Ahmad, Rizwan
author_facet Chen, Chong
Vornehm, Marc
Bu, Zhenyu
Chandrasekaran, Preethi
Sultan, Muhammad A.
Arshad, Syed M.
Liu, Yingmin
Han, Yuchi
Ahmad, Rizwan
contents Purpose: To develop a reconstruction framework for 3D real-time cine cardiovascular magnetic resonance (CMR) from highly undersampled data without requiring fully sampled training datasets. Methods: We developed a multi-dynamic low-rank deep image prior (ML-DIP) framework that models spatial image content and deformation fields using separate neural networks. These sub-networks are jointly trained per scan to reconstruct the dynamic image series directly from undersampled k-space data. ML-DIP was evaluated on (i) a 3D cine digital phantom with simulated premature ventricular contractions (PVCs), (ii) ten healthy subjects (including two scanned during both rest and exercise), and (iii) 12 patients with a history of PVCs. Phantom results were assessed using peak signal-to-noise ratio (PSNR) and structural similarity index measure (SSIM). In vivo performance was evaluated by comparing left-ventricular function quantification (against 2D real-time cine) and image quality (against 2D real-time cine and binning-based 5D-Cine). Results: In the phantom study, ML-DIP achieved PSNR > 29 dB and SSIM > 0.90 for scan times as short as two minutes, while recovering cardiac motion, respiratory motion, and PVC events. In healthy subjects, ML-DIP yielded functional measurements comparable to 2D cine and higher image quality than 5D-Cine, including during exercise with high heart rates and bulk motion. In PVC patients, ML-DIP preserved beat-to-beat variability and reconstructed irregular beats, whereas 5D-Cine showed motion artifacts and information loss due to binning. Conclusion: ML-DIP enables high-quality 3D real-time CMR with acceleration factors exceeding 1,000 by learning low-rank spatial and motion representations from undersampled data, without relying on external fully sampled training datasets.
format Preprint
id arxiv_https___arxiv_org_abs_2507_19404
institution arXiv
publishDate 2025
record_format arxiv
spellingShingle A multi-dynamic low-rank deep image prior (ML-DIP) for 3D real-time cardiovascular MRI
Chen, Chong
Vornehm, Marc
Bu, Zhenyu
Chandrasekaran, Preethi
Sultan, Muhammad A.
Arshad, Syed M.
Liu, Yingmin
Han, Yuchi
Ahmad, Rizwan
Image and Video Processing
Purpose: To develop a reconstruction framework for 3D real-time cine cardiovascular magnetic resonance (CMR) from highly undersampled data without requiring fully sampled training datasets. Methods: We developed a multi-dynamic low-rank deep image prior (ML-DIP) framework that models spatial image content and deformation fields using separate neural networks. These sub-networks are jointly trained per scan to reconstruct the dynamic image series directly from undersampled k-space data. ML-DIP was evaluated on (i) a 3D cine digital phantom with simulated premature ventricular contractions (PVCs), (ii) ten healthy subjects (including two scanned during both rest and exercise), and (iii) 12 patients with a history of PVCs. Phantom results were assessed using peak signal-to-noise ratio (PSNR) and structural similarity index measure (SSIM). In vivo performance was evaluated by comparing left-ventricular function quantification (against 2D real-time cine) and image quality (against 2D real-time cine and binning-based 5D-Cine). Results: In the phantom study, ML-DIP achieved PSNR > 29 dB and SSIM > 0.90 for scan times as short as two minutes, while recovering cardiac motion, respiratory motion, and PVC events. In healthy subjects, ML-DIP yielded functional measurements comparable to 2D cine and higher image quality than 5D-Cine, including during exercise with high heart rates and bulk motion. In PVC patients, ML-DIP preserved beat-to-beat variability and reconstructed irregular beats, whereas 5D-Cine showed motion artifacts and information loss due to binning. Conclusion: ML-DIP enables high-quality 3D real-time CMR with acceleration factors exceeding 1,000 by learning low-rank spatial and motion representations from undersampled data, without relying on external fully sampled training datasets.
title A multi-dynamic low-rank deep image prior (ML-DIP) for 3D real-time cardiovascular MRI
topic Image and Video Processing
url https://arxiv.org/abs/2507.19404